초록
The study was carried out to develope quantitative analysis method of individual sugars in licorice extract. Individual sugars were analyzed by HPLC equipped with Refractive Index(RI) Detector. R values of sucrose and glucose were 1.0000 and R values of fructose and maltose were 0.9999. Standard calibration curve showed good linearity. Detection limit of sugars was in the range of 1.58 to 3.92 ${\mu}g$. Recovery rate of fructose, glucose, sucrose and maltose was $99.4\~102.2\%,\;92.3\~97.9\%,\;99.4\~102.0\%,\;91.1\~101.0$ respectively. Measure uncertainty was calculated to confirm trust and accuracy of analytical results. Main uncertainty factors were standard purity and HPLC replication injection. In $95\%$ trust level expanded uncertainty of sugars in licorice extract were fructose $1.98\pm0.047,\;glucose\;1.32\pm0.065,\;sucrose\;11.69\pm1.177,\;maltose\;1.06\pm0.042\;g/100\;g$.