A Study on Safety Assessment of CTC/EI Interface

열차집중제어장치와 전자연동장치 인터페이스의 안전성평가에 관한 연구

  • 신석균 (㈜마이크로트랙 RAMS 사업부) ;
  • 이기서 (광운대학교 정보제어공학과)
  • Published : 2005.07.01

Abstract

In this paper we analyzed a dangerous failure and a safety requirement based on HIA (Hazard Identification and Analysis) of an interface model between CTC (Centralized Traffic Control) system and El (Interlocking) system, and assigned SU (Safety Integrity Level) by way of an risk estimation of the interface, which employed PHA (Preliminary Hazard Analysis) for the interface of the track control system, being managed as separated system between the centralized traffic control system and the interlocking system, An estimation which satisfies a safety reference of the international standard has been achieved through a quantification of the system failure rate and the dangerous failure rate of the interface model.

Keywords

References

  1. 김영태 저, 2003, '신호제어시스템', P.86-99, 2003
  2. International Standard IEC61508 'Functional Safety of Electrical/Electronic/Programmable electronic Safety-related systems', Part 1 'General Requirements', P65, 1998
  3. Jan Pukite, 'Modeling for Reliability Analysis', IEEE Press, P.38-39, 1998
  4. Felix Redmill et al. 'System Safety : HAZOP and Software HAZOP' , John Wiley & Sons, P.72-104, 1999
  5. Defence Standard 00-58, 'HAZOP Studies on System Containing Programmable Electronics', P5-P25, 2000
  6. International Standard IEC61882 'HAZOP Studies-Application guide', PI0-P21, 1999