DOI QR코드

DOI QR Code

Determination of Bumetanide in Human Plasma by a Validated HPLC Method and Its Application to Single-dose Pharmacokinetics

사람 혈장 중 부메타니드의 HPLC 분석법 검증 및 단일 용량 투여에 의한 약물동태 연구

  • Published : 2005.02.20

Abstract

A high-performance liquid chromatographic method was employed for the determination of bumetanide in human plasma. After addition of internal standard (IS, naproxen) and acidification of the plasma with 1 M hydrochloric acid, the drug and IS were extracted into dichloromethane. The organic phase was back-extracted into 1 M sodium bicarbonate solution and 50 ${\mu}l$ of the aqueous phase was injected onto a reversed-phase C18 column with a mobile phase consisting of methanol: water: glacial acetic acid = 65 : 35 : 1. The samples were detected utilizing a fluorescence detector (excitation wavelength 235 nm, emission wavelength 405 nm). The method was specific and validated with a lower limit of 5 ng/mL. Intra- and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification. The applicability of the method was demonstrated by analysis of plasma after oral administration of a single 2 mg dose to 24 healthy subjects. From the plasma bumetanide concentration vs. time curves, the mean AUC was $246.5{\pm}73.8\;ng{\cdot}hr/mL$ and $C_{max}$ of $132.1{\pm}40.9$ ng/mL reached 1.2 hr after administration. The mean biological half-life of burnet ani de was $1.1{\pm}0.2$hr. Based on the results, this simple and validated assay method could readily be used in any pharmacokinetic or bioequivalence studies using humans.

Keywords

References

  1. E.H. Ostergaard, M.P. Magnussen, C.K. Nielsen, E. Eilertsen and H.H. Frey, Pharmacological properties of 3-n-butylamino-4-phenoxy-5-sulfarnylbenzoic acid (Bumetanide), a new potent diuretic, Arzneimiitelforschung, 22, 66-72 (1972)
  2. M.J. Asbury, P.B. Gatenby, S. OSullivan and E. Bourke, Bumetanide: potent new 'loop' diuretic, Br. Med. J., 1, 211-213 (1972) https://doi.org/10.1136/bmj.1.5794.211
  3. K.H. Olesen, B. Sigurd, E. Steiness and A. Leth, Bumetanide, a new potent diuretic. A clinical evaluation in congestive heart failure, Acta. Med. Scand., 193, 119-131 (1973)
  4. D.L. Davies, A.F. Lant, N.R. Millard, A.J. Smith, J.W. Ward and G.M. Wilson, Renal action, therapeutic use, and pharmacokinetics of the diuretic bumetanide, Clin. Pharmacal. Ther., 15,141-155 (1974) https://doi.org/10.1002/cpt1974152141
  5. E. Bourke, M.J.A. Asbury, S. O'Sullivan and P.B.B. Gatenby, The sites of action of bumetanide in man, Eur. J. Pharmacol., 23, 283-289 (1973) https://doi.org/10.1016/0014-2999(73)90096-4
  6. S.G. Kariander, R. Henning and O. Lundvall, Renal effects of bumetanide, a new saluretic agent, Eur. J. Clin. Pharmacol., 6, 220-223 (1973) https://doi.org/10.1007/BF00644735
  7. J.B. Puschett, Renal effects of bumetanide, J. Clin. Pharmacol., 21, 575-580 (1981) https://doi.org/10.1002/j.1552-4604.1981.tb05666.x
  8. G.K. McEvoy, O.H. Welsh Jr. and E.K. Snow, American Hospital Formulary Service, 41th eds., ASHP, Bethesda, U.S.A., pp. 2314-2319 (1999)
  9. D.E. Smith, High-performance liquid chromatographic assay for bumetanide in plasma and urine, J. Pharm. Sci., 71, 520-523 (1982) https://doi.org/10.1002/jps.2600710510
  10. H. Bokens, C. Bouscheidt and R.F. Muller, Determination of bumetanide in plasma by high-performance liquid chromatography, J. Chromatogr. B., 434, 327-329 (1988) https://doi.org/10.1016/0378-4347(88)80097-5
  11. T.G. Wells, I.R. Hendry and G.L. Kearns, Measurement of bumetanide in plasma and urine by high-performance liquid chromatography and application to bumetanide disposition, ibid, 570, 235-242 (1991) https://doi.org/10.1016/0378-4347(91)80222-X
  12. A.A. Halazo, W.A. Colburn, J.H. Gustafson, R.L. Young, and M. Parsonnet, Pharmacokinetics of bumetanide following intravenous, intramuscular, and oral administrations to normal subjects, J. Pharm. Sci., 73, 1108-1113 (1984) https://doi.org/10.1002/jps.2600730821
  13. W.R. Dixon, R.L. Young, A. Halazo, M.L. Jack, R.E. Weinfeld, K. Alexander, A. Liebman and S.A Kaplan, Bumetanide: radioimmunoassay and pharmacokinetic profile in humans, ibid, 65, 701- 704 (1976) https://doi.org/10.1002/jps.2600650518
  14. A.S. Singh, C. McArdle, B. Gordon, M. Ashraf and K. Granley, Simultaneous analysis of furosemide and bumetanide in horse plasma using high performance liquid chromatography, Biomed. Chromatogr., 3, 262-265 (1989) https://doi.org/10.1002/bmc.1130030607
  15. 식품의약품안전청 고시 제 2002-60호, 생물학적동등성 시험기준 (2002. 11. 22)