Abstract
This study is to find out how organic solvent will be propagated from painting inside the steel box girder of bridge. $2.9m{\times}3.0m$ of inside size of steel box girder is not suitable for painters to do his work comfortably and hygienically. Substance density(ppm)inside the space of the box unsatisfactory hygienical condition. Most of organic solvent(mainly toluene) came down to 0.5m in two minutes and 53sec. But personal protection for painter should be properly kept against flying this heavy organic solvent. longitudinally 27.1m in length is a cell unit of the whole length of bridge. Model XP-3l6A made in Japan is a main instrumentation adjusted to sense organic solvent especially toluene which can be measured up to 10,000ppm. Scenario analysis by computer program, safer release 2.0 has been performed first to estimate how the organic solvent will be propagated. And then actual test was done as a model. This has been measured for approximately five(5) minutes, with 30 sec interval. Actual measurement results showed much higher $10{\sim}20%$ than result analyzed by the computer program, meaning that this painting work can give worse effect to the worker who is painting inside the box girder of the bridge. The first meas urement level over the floor set up at 30cm height from the floor, because organic solvent was estimated to stay at the level. and then, they were measured at 1.0m, 1.5m level respectively, more.