DOI QR코드

DOI QR Code

Chemiluminescence System with Air Pump as a Sensor for Determination of Metal Levels in Rain

  • Hong, Hyuck-Gi (Department of Chemistry, Dankook University) ;
  • Lim, H.B. (Department of Chemistry, Dankook University)
  • Published : 2005.12.20

Abstract

A lab-made chemiluminescence system with air pump was developed for monitoring of some metal levels in rain. The air pump enabled injection of 17.7 $\mu$g samples into a glass cell filled with luminol-$H_2O_2$ reagent of typically 300 $\mu$L for chemiluminescence measurement. The monitored trend of total metal ions in the rain collected in our campus was compared with analytical results of each metal ion from GFAAS. The system was also demonstrated to determine $Cr^{6+}$ by reduction to $Cr^{3+}$ using $SnCl_2$. The limit of detection for $Cr^{6+}$ obtained by 4 measurements was 85.0 pg $mL^{-1}$ with a relative standard deviation of 3.4%. Although this system doesn’t have selectivity due to the characteristics of chemiluminescence, application of it to environmental monitoring as a sensor for some transition metal ions was demonstrated.

Keywords

References

  1. Chon, H. T.; Ahn, J. S.; Jung, M. C. Environ. Geochem. Health 1998, 20, 77 https://doi.org/10.1023/A:1006593708464
  2. Hirata, S.; Yoshihara, H.; Aihara, M. Talanta 1999, 49, 1059 https://doi.org/10.1016/S0039-9140(99)00061-2
  3. Croot, P. L.; Laan, P. Anal. Chim. Acta 2002, 466, 261 https://doi.org/10.1016/S0003-2670(02)00596-2
  4. Sekaly, A. L. R.; Chakrabarti, C. L.; Back, M. H.; Gregoire, D. C.; Lu, J. Y.; Schroeder, W. H. Anal. Chim. Acta 1999, 402, 223 https://doi.org/10.1016/S0003-2670(99)00529-2
  5. Santosa, S. J.; Tanaka, S. Anal. Lett. 1995, 28, 509 https://doi.org/10.1080/00032719508001113
  6. Hoffmann, P.; Karandasev, V. K.; Sinner, T.; Ortner, H. M. Fresenius' J. of Anal. Chem. 1997, 357, 1142 https://doi.org/10.1007/s002160050320
  7. Baechmann, K.; Haag, I.; Steigerwald, K. Atmosph. Environ. 1995, 29, 175 https://doi.org/10.1016/1352-2310(94)00232-A
  8. Hiraide, M.; Chen, Z. S.; Kawaguchi, H. Anal. Sci. 1995, 11, 333 https://doi.org/10.2116/analsci.11.333
  9. Kawakubo, S.; Iwatsuki, M. Anal. Sci. 2000, 16, 945 https://doi.org/10.2116/analsci.16.945
  10. Escobar, R.; Lin, Q.; Guiraum, A. Analyst 1993, 118, 643 https://doi.org/10.1039/an9931800643
  11. Steitz, W. R.; Suydam, W. W.; Hercules, D. M. Anal. Chem. 1972, 44, 957 https://doi.org/10.1021/ac60314a011
  12. Paleologos, E. K.; Vlessidis, A. G.; Karayannis, M. I.; Evmiridis, N. P. Anal. Chim. Acta 2003, 477, 223 https://doi.org/10.1016/S0003-2670(02)01429-0
  13. Zhang, Z.; Qin, W.; Liu, S. Anal. Chim. Acta 1995, 318, 71 https://doi.org/10.1016/0003-2670(95)00415-7
  14. Yang, W.-P.; Zhang, Z.-J.; Deng, W. J. of Chromato. A 2003, 1014, 203 https://doi.org/10.1016/S0021-9673(03)00940-3
  15. Yang, W.-P.; Zhang, Z.-J.; Deng, W. Anal. Chim. Acta 2003, 485, 169 https://doi.org/10.1016/S0003-2670(03)00421-5
  16. Schulman, S. G.; Schulman, J. M.; Rakicioglu, Y. Chemiluminescence in Analytical Chemistry; Garcia-Campana, A. M.; Baeyens, W. R. G., Eds.; Marcel Dekker, Inc.: New York, 2001; Chap. 3, p 77
  17. Murillo Pulgarin, J. A.; Garcia Bermejo, L. F.; Rubio Aranda, J. A. Anal. Chim. Acta 2004, 517, 111 https://doi.org/10.1016/j.aca.2004.04.057

Cited by

  1. System vol.60, pp.1, 2012, https://doi.org/10.1002/jccs.201200086
  2. Determination of Epinephrine Using Sodium Iodate in Chemiluminescence vol.28, pp.12, 2007, https://doi.org/10.5012/bkcs.2007.28.12.2315