Abstract
The purpose of this study is to obtain practical information about membrane coupled $ A_2O$ system for muncipal wastewater treatment. A flat-plate microfiltration (MF) module with a pore size $0.25\;{\mu}m$ was submerged into the aeration basin and treated water was filtrated through the membrane by continuous suction with low pressure. The system was operated with synthetic wastewater to find operational parameters of internal recycle ratio and maximum MLSS showing best water quality and long-term stability. The internal recycle was defined as type 1 for aerobic to anoxic tank and type 2 for anoxic to anaerobic tank, respectively When the flux was maintained at $0.015\;m^3/m^2/hr$ (15 LMH) with 2Q type 1 internal recycle ratio, the optimal operational setting were 10 internal recycle ratio for type 2 and maximum MLSS of 11,000 mg/L among tested conditions. At this condition, removal efficiencies of BOD, CODcr, T-N and T-P showed $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$, respectively.
본 연구의 목적은 도시 하수처리를 위한 막결합형 $A_2O$공정에 관해 실제적인 정보를 얻고자 하는 것이다. 공경 $0.25\;{\mu}m$의 평판형 정밀여과막을 공기가 주입되는 호기조에 침지시켜 처리수는 저압으로 여과된다. 인공폐수를 대상으로 최적의 처리수질과 장기운전의 안정성 확보를 위한 내부반송율과 MLSS 농도 등의 최적 운전인자를 산정하고자 하였다. 내부반송은 각각 호기조에서 무산조로 반송한 것을 type 1, 무산조에서 혐기조로 반송한 것을 type 2라고 규정지었다. 플럭스는 15 LMH, type 1을 2Q로 고정하고 실험하였을 때 최적의 운전 조건은 MLSS 농도는 11,000 mg/L, type 2가 IQ로 나타났다. 이때, BOD $COD_{cr}$, T-N, T-P의 제거율이 각각 $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$로 타 내부반송율보다 효과적이었다.