PRELIMINARY RESULTS OF THE BEAM CONTROL AND DETECTION OF THE KIRAMS ELECTRON MICROBEAM SYSTEM

  • SUN G.M. (Korea Institute of Radiological and Medical Sciences) ;
  • KIM E.H. (Korea Institute of Radiological and Medical Sciences) ;
  • SONG K.B. (Korea Institute of Radiological and Medical Sciences) ;
  • JEONG J.W. (Korea Institute of Radiological and Medical Sciences) ;
  • CHOI H.D. (Korea Institute of Radiological and Medical Sciences)
  • Published : 2005.04.01

Abstract

The Korea Institute of Radiological and Medical Sciences (KIRAMS) electron microbeam system has been built with its prototype components. The system is composed of an electron gun, a beam transport chamber, and a cell image acquisition and positioning stage. Each component has been upgraded through repetitive performance tests for various parametric arrangements. This paper presents the preliminary results of the performance test on the beam control and detection parts of the system.

Keywords

References

  1. R.E. Zirkle and W. Bloom. 'Irradiation of parts of individual cells', Science, 117, 467 (1953) https://doi.org/10.1126/science.117.3045.487
  2. L.A. Braby and W.D. Reece, 'Studying low dose effects using single particle microbeam irradiation', Radiat. Prot. Dosim., 31, 311 (1990)
  3. G. Randers-Pehrson, C.R. Geard, G. Johnson, C.D. Elliston and D.J. Brenner. 'The Columbia University single-ion microbeam', Radiat. Res., 156, 210 (2001) https://doi.org/10.1667/0033-7587(2001)156[0210:TCUSIM]2.0.CO;2
  4. M. Folkard, B. Vojnovic, K.M. Prise, A.G. Bowey, R.J. Locke, G. Schettino and B.D. Michael. 'A chargedparticle microbeam: I. Development of an experimental system for targeting cells individually with counted particles', Int. J. Radiat. Biol., 72, 375 (1997) https://doi.org/10.1080/095530097143158
  5. M. Folkard, G. Schettino, B. Vojnovic, S. Gilchrist, A.G. Michette, S.J. Pfauntsch, K.M. Prise and B.D. Michael. 'A focused ultrasoft x-ray microbeam for targeting cells individually with submicrometer accuracy', Radiat. Res., 156, 796 (2001) https://doi.org/10.1667/0033-7587(2001)156[0796:AFUXRM]2.0.CO;2
  6. S.G. Sawant, G. Randers-Pehrson, C.R. Geard, D.J. Brenner and E.J. Hall. 'The bystander effect in radiation oncogenesis: I. Transformation in C3H 10T1/2 cells in vitro can be initiated in the unirradiated neighbors of irradiated cells', Radiat. Res., 155, 397 (2001) https://doi.org/10.1667/0033-7587(2001)155[0397:TBEIRO]2.0.CO;2
  7. M.A. Kadhim, S.J. Marsden, D.T. Goodhead, A.M. Malcolmson, M. Folkard, K.M. Prise and B.D. Michael. 'Long-term genomic instability in human lymphocytes induced by single-particle irradiation', Radiat. Res., 155, 122 (2001) https://doi.org/10.1667/0033-7587(2001)155[0122:LTGIIH]2.0.CO;2
  8. W.E. Wilson, D.J. Lynch, K. Wei, and L.A. Braby. 'Microdosimetry of a 25 keV electron microbeam', Radiat. Res., 155, 89 (2001) https://doi.org/10.1667/0033-7587(2001)155[0089:MOAKEM]2.0.CO;2
  9. M.C. Choi, E.H. Kim, K.B. Song, D.H. Lee and S.W. Park, J.W. Jeong, G.M. Sun and H.D. Choi. 'Design and operation specification of an electron microbeam system for investing cellular radiation effect', J. Nucl. Sci. and Tech., Suppl. 4. 227 (2004)
  10. E.H. Kim, M. Chang, M.C. Choi and C.S. Kang. 'Dosimetric aspects of the electron microbeam irradiation system for use in low-dose radiation effect study', J. Nucl. Sci. and Tech., Suppl. 4. 223 (2004)
  11. J.W. Jeong, G.M. Sun, H.D. Choi, E.H. Kim, M.C. Choi and H.B. Song. 'Detection system in KIRAMS electron microbeam system', Proc. Korean Nucl. Soc. Annual Meeting, Yongpyong, Korea, Oct. 30-31, 2003
  12. L.A. Braby, A.L. Brooks and N.F. Metting. 'Cellular effects of individual high-linear energy transfer particles and implications for tissue response at low doses', Radiat. Res., 148, S108 (1997) https://doi.org/10.2307/3579724
  13. I. Kawrakow and D.W.O. Rogers. 'The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport', Technical Report PIRS-701, National Research Council of Canada (2000)