References
- J. I. Suzuki, N. Yanagihara, M. Toriyama, and N. Sakabe, 'Principle, Construction and Indication of the Middle Ear Implant', Advanced in Audiology, Vol. 4, pp. 15-21, 1988
- R. L. Goode, M. L. Rosenbaum, and A. J. Maniglia, 'The History and Development of the Implantable Hearing Aid', The Otolaryngologic Clinics of North America, Vol. 28, pp. 1-16, 1995
- B. S. Song, T. Y. Jung, S. P. Chae, M. N.Kim, and J. H. Cho, 'Proposal and evaluation of vibration transducer with minimal magnetic field interference for use in IME system by in-vitro experiment', IEICE Transactions on electronics, Vol E.85-C, No.6, pp.1374-1377, 2002
- H. A. Abbass, M. Kane, S. Garverick, W. H. Ko, and A. J. Maniglia, 'Mechanical, Acoustic and Electromagnetic Evaluation of Semi-implantable Middle Ear Hearing Device (SIMEHD)', ENT-Ear, Nose & Throat Journal, Vol. 76, No 5, pp.321-327, 1997
- A. Vujanic, R. Pavelka, N. Adamovic, C. Kment, S. Mitic, W. Brenner, and G. Popovic, 'Development of a totally implantable hearing aid', 23rd International Conference on MIEL, Vol. 1, pp. 235- 238, 2002
- K. B. Huettenbrink, 'Current status and critical reflections on implantable hearing aids', The American Journal of Otology, Vol. 20, pp. 409-415, 1999
- A. E. Deddens, E. P. Wilson, T. H. J. Lesser, and J. M. Fredrickson, 'The effects of skin thickness on microphone function', American Journal of Otolaryngology, Vol. 11, No.1, pp. 1-4, 1990 https://doi.org/10.1016/0196-0709(90)90162-O
- H. Leysieffer, J. W. Baumann, G. Muller, and H. P. Zenner, 'An implantable piezoelectric hearing aid transducer for sensorineural hearing loss', HNO 45, pp. 792-800, 1997
- I. L. Grant, K. Kroll, E. B. Welling, and S. C. Levine, Optimizing the position and force of a piezoelectric malleus sensor, Hearing Aid Research and Development Conference, National Institutes of Health, Bethesda, Maryland, pp. 22-24, 1997
- B. Rafaely, N. A. Shusina, and J. L. Hayes, 'Robust compensation with adaptive feedback cancellation in hearing aid', Speech Communication, Vol. 39, No. 1-2, pp. 163-170, 2003 https://doi.org/10.1016/S0167-6393(02)00065-1
- N. Yanagihara, Y. Hinohira, and K. Gyo, 'Surgical rehabilitation of deafness with partially implantable hearing . aid using piezoelectric ceramic bimorpli ossicular vibrator', Auris, Nasus, Larynx, Vol. 24, No.1, pp. 91-98, 1997 https://doi.org/10.1016/S0385-8146(96)00025-9
- M. Dimitrios, and Tsamados, 'Fluid-Solid Interaction and Modal Analysis of a Miniaturized Piezoresistive Pressure Sensor', Ansys conference, No.169, 2004