Abstract
The criticality analysis method using HELIOS-MASTER code system, which is the nuclear core analysis code system, was developed for the spent fuel storage of SMART-P reactor. We generated the macroscopic cross section of the geometric model with HELIOS and estimated the criticality of the 3-dimensional model with MASTER for SMART-P spent fuel storage. The validity of criticality analysis method for SMART-P spent fuel storage with the HELIOS-MASTER code system by 3-D MCNP calculation was also verified. The result of the criticality analysis with the HELIOS-MASTER code system is more conservative than that with the MCNP and the accuracy of this result is within the range of an allowable error. Because HELIOS-MASTER can perform the 3-D depletion calculation lot a spent fuel storage, it will be useful to perform the criticality analysis including a burnup credit in future.
노심설계 해석체계로 사용하는 HELIOS-MASTER코드를 이용하여 SAMRT연구로 사용 후 핵연료 저장조에 대한 임계도 해석체계를 개발하였다. 저장조의 기하학적 모형에 대한 거시 단면적을 HELIOS코드를 이용하여 생산하고, 저장조의 3차원 모델에 대한 임계도를 MASTER코드로 평가하였다. 또한 3차원 MCNP계산을 통하여 HELIOS-MASTER체계를 이용한 임계도 평가의 타당성을 검증하였다 HELIOS-MASTER코드 체계를 이용한 임계도 해석결과가 약간 보수적인 방향으로 허용오차 범위 내에서 정확도를 유지하였다. HELIOS-MASTER 코드 체계는 3차원 연소계산이 가능하기 때문에 차후에 연소이력을 고려한 사용후 연료 저장조에 대한 임계해석에 유용할 것이다.