Design of a High Efficiency Neutron Detector Using a GEM

GEM을 이용한 고효율 중성자 검출기 설계

  • Published : 2005.03.30

Abstract

The radiation detector research group at KAERI has developed a high efficiency neutron detector using a Gas Electron Multiplier (GEM). The double GEM was fabricated and operated in an Ar/Isobutane mixture. For an application to a high efficiency neutron detector, $^6Li\;or\;^{10}B$ neutron converters coated on each surface of the multi GEM foils were considered. The optimized thickness of the thin film for a neutron detection was calculated with the MCNP and SRIM. The neutron efficiency was calculated by changing the chemical components of the thin film, and the thickness of the thin film. The thermalized neutrons were measured by a GEM detector with a thin neutron converter on the drift plate.

한국원자력연구소의 방사선 검출기 연구팀에서는 가스 전자 증폭기를 이용하여 고효율 중성자 검출기를 개발하고 있다. 이중 가스 전자 증폭기를 제작하였고 Ar/Isobutane 혼합기체에서 동작시켰다. 고효율 중성자 검출기에 적용하기 위해서 다중 가스 전자 증폭기 포일 양면에 중성자 변환 물질인 $^6Li$ 또는 $^{10}B$를 코팅하는 것이 고려되었다. 중성자 검출을 위한 박막의 최적화된 두께를 MCNP와 SRIM으로 계산하였다. 중성자 검출 효율은 박막을 구성하는 화합물과 박막 두께를 변화시키면서 계산하였다. 열중성자는 drift plate에 중성자 반응 박막을 입힌 GEM 검출기에 의해서 측정되있다.

Keywords

References

  1. D. S. McGregor, R. T. Klann, H. K. Gersch, and Y. H. Yang, 'Thin-film coated bulk GaAs detectors for thermal and fast neutron measurements', Nucl. Instr. Met. A466(1), 126-141(2001)
  2. F. Sauli, 'Development and application of gas electron multiplier detectors', Nucl. Instr. Meth. A505(1-2), 195-198(2003)
  3. B. Gebauer, 'Toward detectors for next generation spallation neutron sources', Nucl. Instr. Meth(in press)
  4. S. H. Park, Y. K. Kim, S. H. Han, J. H. Ha, B. S. Moon, and C. E. Chung, 'Ion Feedback Effect in the Multi GEM Structure', Jour. Kor. Phys. Soc, 43(3), 332-335(2003)
  5. Y. K. Kim, S. H. Park, S. H. Han, and J. H. Ha, 'Operational properties of the double Gas Electron Multiplier', Jour. Nucl. Sci. Tech, 4, 295-298(2004)