DOI QR코드

DOI QR Code

Integrated function evaluation of efficient micromixer and application to glucose-catalysts reaction

효율적인 Micromixer의 통합된 기능 평가 및 Glucose-Catalysts 반응에 적용

  • Published : 2005.09.30

Abstract

In this paper, the PDMS based micromixer having 3-dimension triangular structure has been developed for the reaction of samples in the micro volume. The mixing efficiency was measured according to the change of Reynolds number (Re: 0.08, 0.8, 8, 16) and channel height (100, 200, $300{\mu}m$). Total length of mixing region is 7.4 mm and the measured mixing efficiencies at the outlet were over 85 %. Within the mixing length 2.4 mm, the mixing efficiencies were more than 70 % at any Reynolds numbers, and this indicates the strong mixing has occurred inside the mixing channel due the triangular structures. By employing these 2 mixers, we have fabricated the microreactor to detect the glucose-catalysts reaction. The microreactor showed good reactivity of glucose and enzymes with the small amount of sample solution.

Keywords

References

  1. G. M. Whitesides, E. Ostuni, S. Takayama, X. Jiang, and D. E. Ingber, 'Soft lithography in biology and biochemistry', Annu Rev Biomed Eng., vol. 3, pp. 335-373, 2001 https://doi.org/10.1146/annurev.bioeng.3.1.335
  2. R. H. Liu, M. A. Stremler, K. V. Sharp, M. G. Olsen, J. G. Santiago, R. J. Adrian, H. Aref, and D. J. Beebe, 'Passive mixing in a three-dimensional serpentine microchannel', J. Microelectromech. Syst., vol. 9, no. 2, pp. 190-197, 2000 https://doi.org/10.1109/84.846699
  3. P. J. A. Kenis, R. F. Ismagilov, S. Takayama, G. M. Whitesides, S. Li, and H.S. White, 'Fabrication inside microchannels using fluid flow', Ace. Chem. Res., vol. 33, no. 12, pp. 841-847, 2000 https://doi.org/10.1021/ar000062u
  4. A. D. Stroock, S. K. Dertinger, A. Ajdari, I. Mezic, H. A. Stone, and G. M. Whitesides, 'Chaotic mixer for microchannels', Science, vol. 295, pp. 647-651, 2001
  5. G. H. Seong and R. M. Crooks, 'Efficient mixing and reactions within microfluidic channels using microbead-supported catalysts', J. Am. Chem. Soc., vol. 124, no. 45, pp. 13360-13361, 2002 https://doi.org/10.1021/ja020932y
  6. H. Suzuki, N. Kasagi, and C. Ho, 'Chaotic mixing of magnetic bead in micro cell seperator', Proc. 3rd Int. Symp. Turbluence and Shear Flow Phenomena, pp. 817-822, Sendai, Japan, 2003
  7. O. J. Kim, H. J. Oh, T. H. Park, J. B. Choo, and S. H. Lee, 'An easily integrative and efficient micromixer and its application to the detection of glucose-catalyst reactions', The Analyst, vol. 130, pp. 293-298, 2005 https://doi.org/10.1039/b414180f
  8. J. Y. Kim, J. Y. Baek, K. A. Lee, and S. H. Lee, 'Automatic aligning and bonding system of PDMS layer for the fabrication of 3D microfluidic channels', Sensors and Actuators A, vol. 119, pp. 593-598, 2005 https://doi.org/10.1016/j.sna.2004.09.023
  9. S. J. Park, J. H. Park, S. Chung, C. Chung, and J. K. Chang, 'Rapid three-dimensional passive rotation micromixer using the breakup process', J. Micromech. Microeng., vol. 14, pp. 6-14, 2004 https://doi.org/10.1088/0960-1317/14/1/302
  10. A. M Jorgensen, K. B. Mogensen, J. P. Kutter, and O. Geschke, 'A biochemical microdevice with an intergrated chemiluminescence detector', Sensors and Actuators B, vol. 90, pp. 15-21, 2003 https://doi.org/10.1016/S0925-4005(03)00016-9
  11. 서희돈, 이영태, 'Stereo lithography을 이용한 마이크로 펌프 제작', 센서학회지, 제10권, 제4호, pp. 232-238, 2001
  12. 이승기, 정승환, 'MEMS 공정을 이용한 전도성 고분자 액추에이터용 마이크로 구조물의 제작', 센서학회지, 제12권, 제4호, pp. 156-163,2003