Measurement of Auto-PEEP

자가 호기말 양압(auto-PEEP)의 측정 방법

  • Sohn, Jang Won (Department of Internal Medicine, Hanyang University College of Medicine) ;
  • Koh, Younsuck (Division of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine)
  • 손장원 (한양대학교 의과대학 내과학교실) ;
  • 고윤석 (울산 대학교 의과대학, 서울 아산 병원 호흡기 내과학교실)
  • Published : 2004.12.30

Abstract

Keywords

References

  1. Tuxen Dr, Lane S. The effects of ventilatory pattern on hyperinflation, airway pressure and circulation in mechanical ventilation of patients with severe airflow obstruction. Am Rev Respir Dis 1987;136:827-9
  2. O'Donnell DE, Bertley JC, Chau LK, Webb KA. Qualitative aspects of exertional breathlessness in chronic airflow limitation: pathophysiologic mechanisms. Am J Respir Crit Care Med 1997;155: 109-15
  3. Haluszka J, Chartrand DA, Grassino AE, Milic-Emili J. Intricsic PEEP and arterial PaCO2 in stable patients with chronic obstructive pulmonary disease. Am Rev Respir Dis 1990;141:1194-7
  4. Kimball WR, Leith DE, Robins AG. Dynamic hyperinflation and ventilator dependence in chronic obstructive pulmonary disease. Am Rev Respir Dis 1982;126:991-5
  5. Pepe PE, Marini JJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. Am Rev Respir Dis 1982;126: 166-70
  6. Marcy TW, Marini JJ. Inverse ratio ventilation in ARDS: rationale and implementation. Chest 1990;100:494-504
  7. Rossi A, Polese G, Brandi G, Conti G. Intrinsic positive end-expiratory pressure (PEEPi). Intensive Care Med 1995;21:522-36
  8. Smith TC, Marini JJ. Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. J Apple Physiol 1998;65:1488-99
  9. Fleury B, Murciano D, Talamo C, Aubier M, Pariente R, Milic-Emili J. Work of breathing in patients with obstructive pulmonary disease in acute res-piratory faikure. Am Rev Respir Dis 1985;131:822-7
  10. Johnson MM, Ely EW, Chiles C, Bowton DL, Frie-manas RI, Choplin RH, et al. Radiographic assessment of hyperinflation: correlation with objective chest radio- graphic measurements and mechanical ventilator parameters. Chest 1998;113:1698-704
  11. Gottfried SB, Reissman H, Ranieri VM. A simple method for the measurement of intrinsic positive end-espiratory pressure during controlled and assisted modes of ventilation. Crit Care Med 1992;20:621-9
  12. Maltais F, Reissmann H, Navalesi P, Hernandez P, Gursahaney A, Ranieri VM, et al. Comparison of static and dynamic measurements of intrinsic PEEP in mechanically ventilated patients. Am J Respir Crit Care Med 1994;150:1318-24
  13. Yan S, Kayser B, Tobiasz M, Sliwinski P. Comparison of static and dynamin intrinsic positive end-expiratory pressure using the Campbell diagram. Am J Respir Crit Care Med 1996;154:938-474
  14. Tobin MJ, Lodato RF. PEEP, auto-PEEP, and water-falls. Chest 1989;96:449-51
  15. Hoggman RA, Ershowsky P, Kreiger BP. Determination of auto-PEEP during spontaneous and controlled ventilation by monitoring changes in end-expiratory thoracic gas volume. Chest 1989;96:613-6
  16. Ranieri VM, Giuliani R, Cinnella G, Pesce C, Brienza N, Ippolito EL, et al. Physiologic effects of positive end-expiratory pressure in patients with chronic obstructive pulmonary disease during acute ventilatory failure and controlld mechanical ventilation. Am Rev Respir Dis 1993;147:5-13
  17. Tuxen DV. Detrimental effects of positive end-expiratory pressure during controlled mechanical ventilation of patients with severe airflow obstruction. Am Rev Respir Dis 1989;140:5-9
  18. Tuxen DV, Williams TJ, Scheinkestel CD, Czarny D, Bowes G. Use of a measurement of pulmonary hyperinflation to control the level of mechanical ventilation in patients with aucte severe asthma. Am Rev Respir Dis 1992;146: 1136-42