FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구

  • Lee Heung-Tae (Dept. of Prosthodontics, College of Dentistry, Chosun University) ;
  • Chung Chae-Heon (Dept. of Prosthodontics, College of Dentistry, Chosun University)
  • 이흥태 (조선대학교 치과대학 보철학교실) ;
  • 정재헌 (조선대학교 치과대학 보철학교실)
  • Published : 2004.04.01

Abstract

Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

Keywords

References

  1. Binon PP. Implants and components:Entering the new millennium. Int J Oral Maxillofac Implants 2000: 5: 76-94
  2. Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces, J Prosthet Dent 2001:86:24-32
  3. Sakaguchi RL, Borgersen SE. Nonlinear finite element contact analysis of preload dental implant components. Int J Oral Maxilofac Implant. 1993: 655-661
  4. Brunski JE, Hipp JE. In the forces on endosteal implant: A measurement system and biomechanical consideration. J Prosthet Dent 1984:51 :82
  5. Sones AD. Complication with osseointegrated implants. J Prosthet Dent 1989: 62:581-585
  6. Boggan RS, Strong TA, Misch CE. Bidez MW. Inf1uence of hex geometry and prostetic table width on statig and fatigue strength of dental implants. J Prosthet Dent 1999: 82: 436-440
  7. Abrahamsson I, Berglundh T. Lindhe J. Soft tissue response to plaque formation at different implant systems. A comparative study in the dog. Clin Oral Implants Res 1998:9:73-79
  8. Quirynen M, Bollen CML. Eyssen H, van Steenberghe D. Microvial penetration along the implant components of the Branemark system. An in vitro study. Clin Oral Implants Res 1994:5:239-244
  9. Gross M. Abramovich I. Weiss EI. Microleakage at the abutment- implant interface of osseointegrated implants. Int J Oral Maxillofac Implants 1999: 14:94-100
  10. Besimo CE, Guindy JS, Lewetag D. Meyer J. Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro. Int J Oral Maxillofac Implants 1999: 14:654-660
  11. Becker W. Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: A retrospective study. J Prosthet Dent 1995:80:184-192
  12. Jemt T, Laney WR, Harris D. Henry, PJ. Krogh P, Polizzi G. Osseointegrated implants for single tooth replacement. A 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991 :6:29-36
  13. Levine RA, et al. A multicenter retro-spective analysis of ITI implant system used for single-tooth replacements: Preliminary results at six or more months of loading. Int J Oral Maxillofacial Implants 1997: 12:237-242
  14. Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997:8:290-298
  15. Norton MR. Assessment of cold welding properties of internal conical interface two commercially available implant system. J Prosthet Dent 1999:81:159-166
  16. Burguette RL, Johns MR, King TB, Patterson EA. Tightening characteristic for screwed joint in osseointegrated dental implant. J Prosthet Dent 1994: 71: 592-599
  17. Binon PP. Evaluation of three slip fit hexagonal implants. Implant Dent 1996: 5:253-248
  18. Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996: 9: 149-152
  19. Binon PP, McHugh MJ. The effect of eliminating implant/ abutment rotation-al misfit on screw joint stability. Int J Prosthodont 1996: 9:511-519
  20. Byren D, Houston F, Cleary R. Claffey N. The fit of cast and premachined implant abutments. J Prosthet Dent 1998:80:184-192
  21. Carr AB, Brunski JB, Hurley E. Effect of fabrication, finishing, and polishing procedures on preload in prostheses using conventional gold and plastic cylinders. Int J Oral Maxillofac Implants 1996: 11:589-598
  22. Carr AB, Brunski JB. Hurley E. The effect of finishing and polishing techniques in implant cylinder preload: 9th Annual Meeting of the Academy of Osseointergration (Abstract). Int J Oral Maxilofac Implants 1995: 10: 123-124
  23. Kim NH, Chung CB, Son MK, Back DB, A study on the fit of the implant-abutment-screw interface. J Korean Acad Prosthodont 2003:41: 503-518
  24. Sutter F, Schroeder A. et al. The new concept of ITI hollow- cylinder and hollow screw implants : Part 1. Engineering and design. Int J Oral Maxilofac Implant. 1988:3: 161-172
  25. Beat R. Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000: 15: 519-526
  26. Ekfeldt A. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study, Int J Oral Maxilofac Implants 1994:179-183
  27. Krennmair G. Schmidinger S, Waldenberger O. Single-tooth replacement with frialit2 system: A retrospective clinical analysis of 146 implants. Int J Oral Maxilofac Implanst. 2002: 17: 78-85
  28. Persson LG. Bacterial colonization on internal surfaces of Branemark system implant components. Clin Oral Impl Res 1996: 7: 90-9