100 kW급 풍력발전기의 하중 측정

Load Measurements of 100 kW Wind Turbine

  • 배재성 (한국에너지기술연구원 풍력유체기기연구센터) ;
  • 김성완 (한국에너지기술연구원 풍력유체기기연구센터) ;
  • 경남호 (한국에너지기술연구원 풍력유체기기연구센터)
  • 발행 : 2004.12.30

초록

Mechanical load measurements on blade and tower of Vestas 100 kW wind turbine has been reformed in Wollyong test site, Jeju island. The experimental procedure for the measurement of wind turbine loads, such as edgewise(lead-lag) bending moment, flapwise bending moment, and tower base bending moment, has been established. The test facilities consisting of strain-gauges, telemetry and T-Mon system are installed in the wind turbine. Strain gauges are on-site calibrated against load cell prior to monitoring the wind turbine loads. Using the test setup, the loads on the components are being measured and analysed for various external conditions of the wind turbine. A set of results for near rated wind speed has been presented in this paper.

키워드

참고문헌

  1. BTM Consult Aps, World Market Update 2003, Denmark, March 2004
  2. IEC, Wind Turbine Generator Systems Part 13 : Measurement of Mechanical Loads, IEC 61400U13, 1992
  3. Morfiadakis, E., Papadopoulos, K. H. Philippidis, T.P., and Lekou, D.J Assessment of the Strain Gauge Technique for Measurement of Wind Turbine Blade Loads, European Wind Energy Conference, Nice, France, 1-5 March 1999 pp. 671-674
  4. Seifert, Henry, DEWI/MADE Load Measurements in Spain, DEWI Magazin, Nr. 15, August 1999, pp. 50-56