References
- Ahmed, B., (1996),"Numerical modeling of connections in composite frames", Ph. D. Thesis, Department of Civil Engineering, University of Nottingham, UK.
- Ahsan, R. (1997),"Semi-rigid joint action in sway steel frames", M. Sc. Thesis, Department of Civil Engineering, Bangladesh University of Engineering and Technology, Dhaka.
- Anderson, D. and Benterkia, Z. (1991),"Analysis of semi-rigid steel frames and criteria for their design", J. Construct. Steel Res., 18(3), 227-237. https://doi.org/10.1016/0143-974X(91)90027-X
- ANSYS (1998),"Basic analysis procedure guide", Elements Reference Vol. 1 & 2, Commands Reference Vol. 1 & 2 and Structural Analysis Guide, Version 5.4, ANSYS, Inc., Global Headquarters, Southpointe, 275 Technology Drive, Canonsburg, PA 15317.
- Ashraf, M. (2001),"Sway estimation of semi-rigid steel frames", M. Sc. Thesis, Department of Civil Engineering, Bangladesh University of Engineering and Technology, Dhaka 1000, Bangladesh.
- Ashraf, M., Nethercot, D.A. and Ahmed, B. (2004),"Sway of semi-rigid steel frames, Part 2: Irregular frames", Accepted for publication in the Journal of Engineering Structures.
- Bangladesh National Building Code (1993),"Housing and building research institute and bangladesh standards and testing institution", 1st Edition, Dhaka.
- Fisher, J.M. and West, M.A. (1990),"Serviceability design considerations for low rise buildings", American Institute of Steel Construction (AISC) Steel Design Guide Series, No. 3, American Institute of Steel Construction (AISC), Chicago, Illinois.
- Kishi, N., Chen, W.F., Goto, Y. and Hasan, R. (1996),"Behavior of tall buildings with mixed use of rigid and semi-rigid connections", Comput. Struct., 61(6), 1193-1206. https://doi.org/10.1016/0045-7949(96)00052-1
- Lui, E.M. and Chen, W.F. (1988),"Behaviour of braced and unbraced semi-rigid frames", Int. J. Solids Struct., 24, 893-913. https://doi.org/10.1016/0020-7683(88)90040-6
- Schueller, W. (1977), High-Rise Building Structures, John Wiley and Sons.
- Task Committee on Drift Control of Steel Building Structures (1988),"Wind drift design of steel-framed buildings: State of the art report", J. Struct. Eng., ASCE, 114(9), 2085-2108. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:9(2085)
- Wang, C.K. (1983), Statically Intermediate Structures, McGraw Hill, New York.
Cited by
- Sway of semi-rigid steel frames, part 2: Irregular frames vol.29, pp.8, 2007, https://doi.org/10.1016/j.engstruct.2006.10.005
- Limiting the sway on multi-storey un-braced steel frames bending on weak axis with partial strength connections vol.38, pp.6, 2004, https://doi.org/10.12989/sem.2011.38.6.825