Abstract
Ductiluty factor has played an important role in seismic design as it is key component of response modification factor(R). In this stuty, ductility factors() are calculated by multiplying ductility factor for SDOF systems() and MDOF modification factors(). Ductility factors() for SDOF systems are computed from nonlinear dynamic analysis undergoing different level of displacement ductiluty demands and period when subjected to a large number of recorded earthquake ground motions. The MDOF modification factors() are proposed to account for the MDOF systems, based on previous studies. A total of 108 prototype steel frames are designed to investigate the ductility factors considering the number of stories(4, 8 and 16-stories), framing system(Perimeter Frames, PF and Distributed Frames, DF), failure mechanism(Strong-Column Weak-Beam, SCWB and Weak-Column Strong-Beam, WCSB), soil profiles(SA, SC and SE in UBC 1997) and seismic zone factors(Z=0.075, 0.2 and 0.4 in UBC 1997). It is shown that the number of stories, failure mechanisms (SCWB, WCSB), and soil profiles have great influence on the ductility factors, however, the structural system(Perimeter frames, Distributed frames), and seismic zones have no influence on the ductility factors.
연성 계수는 반응수정계수(R)의 핵심구성요소로서 내진설계에서 중요한 역할을 하는 계수이다. 본 연구에서의 연성계수()는 단자유도 구조물의 연성계수()에 다자유도 보정계수()를 곱하여 평가하였다. 단자유도 시스템의 연성계수는 지진하중을 받는 단자유도 구조물의 변위 연성요구도와 주기에 따른 비선형 동적해석으로부터 산정하였다. 다자유도 시스템의 영향을 고려하기 위한 다자유도 보정계수()는 기존의 연구에 근거하여 제시하였다. 철골 연성 모멘트 골조의 연성계수를 평가하기 위하여, 구조물의 층수, 골조시스템(외곽골조, 분배골조), 붕괴 메카니즘(강-기둥 약-보, 약-기둥 강-보), 토질조건 및 지진구역을 변수로 하여 총 108개의 예제 구조물을 설계하였다. 구조물의 층수, 붕괴 메카니즘 및 토질조건은 연성계수에 큰 영향을 미치는 반면, 골조 시스템 및 지진구역은 연성계수에 영향을 미치지 않는 것으로 나타났다.