Methyl yellow와 Methyl orange 지시약을 이용한 실내공기중의 포름알데히드 간이측정기에 대한 연구

A Study on a Passive Sampler for Indoor Formaldehyde Using Methyl Yellow and Methyl Orange Indicator

  • 정상진 (경기대학교 토목환경공학부 환경공학전공) ;
  • 장재철 (경기대학교 토목환경공학부 환경공학전공)
  • 발행 : 2004.12.01

초록

A passive sampler has been developed for measuring formaldehyde in air using methyl yellow and methyl orange indicator. It is based on the color change of the TLC plate on reaction with formaldehyde. TLC plates impregnated with three kinds of solutions containing methyl orange, methyl yellow, mixing of methyl yellow and methyl orange were shown rectilinear response to formaldehyde concentration at constant exposure time. The color change of impregnated TLC plate with criteria air pollution, such as NO$_2$, SO$_2$, CO, $O_3$ was investigated. The color change of TLC plate with $O_3$ is larger than other gases.

키워드

참고문헌

  1. 이인규, 김정한, 노영쇠, 신대현, 윤성화, 조인호, 하현준 (1993) 유기화학, 회중당, 704
  2. 정상진 (2002) 오존 간이측정기에 대한 연구(I) 필터의 민감도, 한국 대기환경학회지, 18(5), 383-391
  3. 환경부 (2004) 다중 이용시설등의 실내공기질 관리법령
  4. 황윤정, 박상곤, 백성옥(1996) 대기 중 카르보닐화함물의 농도측정-분석 방법의 평가와 실제에의 적용,한국대기보전학회지, 12(2), 199-209
  5. 황윤정, 박상곤, 백성옥 (1998) 공기 중 포름알데히드 측정을 위한 크로모트로핀산법과 DNPH/HPLC방법의 비교.평가, 한국대기보전학회지, 14(3), 519-524
  6. 홍상범, 정용국, 이재훈, 김민영, 여인학(2001) 대기 중 HCHO의 측정을 위한 pyrex coil-HPLC 법 에 관한 연구, 한국대기환경학회 2001 추계학술대회 논문집, 333-334
  7. Frieldfeld, S. and M. Fraser (2000) Field intercomparison of novel optical sensor for formaldehyde quantification, Geophysical Research Letters, 27(14), 2093-2096
  8. Gayathri , N. and N. Balasubramanian(2001) Determination of Formaldehyde in Effluents of Electroless Plating Baths Metal Finishing , Pollution control , Novem ber, 2001, 33- 36
  9. Grosjean, D. and E.L. Williams II(1992) A passive sampler for airborne formaldehyde, Atmospheric Environment, 26(16), 2923-2928
  10. Hauser, T.R. and R.L. Cummins (1964) Increasing Sensitivity of Aliphatic Aldehydes in Air, Anal. Chem., 36, 679-681
  11. Levin, J., R. Lindahl, and K. Andersson (1989) Monitoring of Parts-Per-Billion Levels of Formaldehyde Using a Diffusive Sampler, JAPCA, 39, 44-47
  12. Nakano, N. and K. Nagashima (1999) An automatic monitor of formaldehyde in air by a monitoring tape method, J. Environ. Monit., 1,255-258 https://doi.org/10.1039/a900410f
  13. Quesenberry, M.S. and Y.C. Lee (1996) A Rapid Formalde hyde Assay Using p urpald Reagent: Application under Periodation Conditions, Ana l. Biochem., 234,50-55
  14. Sekine, Y. (2002) Oxidative decomposition of formaldehyde by metal oxides at room temperature, Atmospheric Environment 36,5543-5547