An Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by Using PIV Technique

  • Chang, Tae-Hyun (Division of Mechanical and Automation Engineering, Kyungnam University) ;
  • Jang, Sung-Cheol (Department of Mechanical Engineering, Kyungnam University Graduate School)
  • Published : 2004.10.01

Abstract

An experimental investigation was performed to study the characteristics of ER (Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D. C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique was employed for velocity measurements. This research found the mean velocity distributions with 0kV /mm, l.0kV /mm and l.5kV /mm for Re=0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF was clearly strong along the test tube and the flow rate decreased. The present results will contribute to the economical and compact design of ER fluids system.

Keywords

References

  1. Brooks D. A., 1992, 'Design and Development of Flow Based Electro-Rheological Devices,' Journal of Modern Physics, Vol. 6, pp. 2705-2730 https://doi.org/10.1142/S0217979292001389
  2. Choi S. B. and Cheong C. C., 1994, 'Performance Investigation of a Cylinderical Valve Featuring Electro-Rheological Fluids,' Korean Socity of Precision Engineering, Vol. 11, pp. 148-157
  3. Jang S. C., Yum M. O. and Kim D. T., 2001, 'The Flow Characteristics of ER Fluids According to th Electrode Shape of Two Parallel-Plate,' proceedings of the KSME 2001 Spring Annual Meeting E, pp. 207-212
  4. Jang S. C., Yum M. O. and Kim D. T., 2003, 'Flow Rate-Pressure Drop Characteristics of Dispersive ER Fluid According to Change of Electric Field Strength in Clearance between Parallel Plates,' KSMTE, Vol. 12, No. 1, pp. 78-83
  5. Jang S. C., Park C. S., Kim K. H. and Yum M. O., 2001, 'The Flow Visualization of ER Fluid between Two Parallel-Plate Electrodes by Narrow Distance,' KSMT, Vol. 3, No. 2, pp. 129-136
  6. Jeon Y. S., 1998, 'Performance Investigation of Cylindrical-Type ER Valves With Different Electrode Length,' Vol. 7, No. 6, pp. 1-11
  7. Nakano M. and Yonekawa T., 1994, 'Pressure Response of ER Fluid in a Piston Cylinder ER Valve System,' Proc. of the 4th Int. Conf. on Electrorheological Fluid, pp. 477-489
  8. Park M. K., Rhee E. J., Shuzo Oshi a and Ryuichiro Yamane, 1999, 'The Flow Visualization of ER Fluid Between Two Parallel-Plate Electrodes Separated by Small Distance,' KSME, Vol. 23, No. 7, pp. 801-810
  9. Simmonds A. J., 1991, 'Electro-Rheological Valves in a Hydraulic Circuit,' lEE Proceeding-D, Vol. 138, No. 4, pp. 400-404 https://doi.org/10.1049/ip-d.1991.0054
  10. Tsukiji T., Takahashi J., Sugimoto H., Ikeda H., 1996, 'Flow Characteristics of ERF between Two Parallel-Plate Electrodes,' JFPS, Vol. 25, No. 4, pp. 104-561
  11. Wang K. C., Mclay R. and Carey G. F., 1989, ER Fluid Modelling, CFD Laboratory, College of Engineering, University of Texas at Austin, Tx, USA. Proc. of the Second International Conference on ERF, pp. 41-52, 1989
  12. Yokota S., Kondoh Y., 1996, 'A Control valve by Making use of an ER Fluid,' JSME, Vol. 62, No. 601, pp. 93-100