An Experimental Study on the Temperature Distribution in IRWST

  • 발행 : 2004.05.01

초록

The In-Containment Refueling Water Storage Tank (IRWST), one of the design improvements applied to the APR -1400, has a function to condense the high enthalpy fluid discharged from the Reactor Coolant System (RCS). The condensation of discharged fluid by the tank water drives the tank temperature high and causes oscillatory condensation. Also if the tank cooling water temperature approaches the saturated state, the steam bubble may escape from the water uncondensed. These oscillatory condensation and bubble escape would burden the undue load to the tank structure, pressurize the tank, and degrade its intended function. For these reasons simple analytical modeling and experimental works were performed in order to predict exact tank temperature distribution and to find the effective cooling method to keep the tank temperature below the bubble escape limit (93.3$^{\circ}C$), which was experimentally proven by other researchers. Both the analytical model and experimental results show that the temperature distributions are horizontally stratified. Particularly, the hot liquid produced by the condensation around the sparger holes goes up straight like a thermal plume. Also, the momentum of the discharged fluid is not so strong to interrupt this horizontal thermal stratification significantly. Therefore the layout and shape of sparger is not so important as long as the location of the sparger hole is sufficiently close to the bottom of the tank. Finally, for the effective tank cooling it is recommended that the locations of the discharge and intake lines of the cooling system be cautiously selected considering the temperature distribution, the water level change, and the cooling effectiveness.

키워드

참고문헌

  1. Cho, S.and Song, C. H., 2001, 'Multiple-Hole Effect on the Performance of a Sparger During Direct Contact Condensation of Steam,' KSME International Journal, Vol. 15, No. 4
  2. Choong-Won Lee, Su-Yeon Moon, Chang-Hyun Sohn and Hyun-Jin Youn, 2003, 'Spray and Combustion Characteristics of a Dump-type Ramjet Combustor, Int. Jr., Vol. 17, No. 12, pp. 2019-2026
  3. Combustion Engineering, 1994, 'System 80+ Standard Safety Analysis Report Design Certification,' Amendment W.
  4. Heoyjung Kim, 1996, 'Safety Requirement in KNGR,' KINS
  5. Holman, J. P., 1989, Experimental Method for Engineers, Fifth Edition, McGraw-Hill, pp 231-241
  6. KEPCO, 1994, 'Elementary Requirement in KNGR.'
  7. KOPEC, 1996, 'IRWST T/H Load Analysis,' KEPCO, Korea
  8. Kangyoul Bae, Hanshik Chung and Hyomin Jeong, 2002, 'Convective Heat Transfer in Ventilated Space with Various Partitions,' KSME Int. Jr., Vol. 16, No. 5, pp. 676-682
  9. Koo-Woun Park, Se-Won Lee, Hee-Jin Ko and Young-Sik Jang, 1997, 'IRWST Hydrodynamic Loads in KNGR,' KOPEC, Korea
  10. Korea Atomic Energy Research Institute, 1994, 'Joint Passive Safety Evaluation Program for System 80+,'
  11. Korean Next Generation Reactor, Center for Advanced Reactor Research, 1994, 'Design Concept - The Total Plant Design (IV)
  12. Kyungho Nam, Hejeon Ko and Jaeyoung Lim, 1996, 'IRWST System Design in KNGR,' Power Engineering, Vol. 7. No. 2, KOPEC
  13. Lubin, B. T., 1991, 'Evaluation of the System 80+ Steam Relief System and IRWST Design.'
  14. Robert P. Benedict, 1977, Fundamentals of Temperature, Pressure and Flow Measurements, Wiley, pp. 443-469
  15. Sangdeuk Park, 1996, 'Design Requirements and Features of Korean Next Generation Reactor, Center for Advanced Reactor Research of KEPRI,' Korea