Multi-modality MEdical Image Registration based on Moment Information and Surface Distance

모멘트 정보와 표면거리 기반 다중 모달리티 의료영상 정합

  • 최유주 (이화여자대학교 컴퓨터학과) ;
  • 김민정 (이화여자대학교 컴퓨터학) ;
  • 박지영 (이화여자대학교 컴퓨터학) ;
  • 윤현주 (이화여자대학교 컴퓨터그래픽스연구센) ;
  • 정명진 (삼성전자 소프트웨어센) ;
  • 홍승봉 (성균관대학교 의과대학, 삼성서울병원 신경) ;
  • 김명희 (이화여자대학교 컴퓨터학과)
  • Published : 2004.04.01

Abstract

Multi-modality image registration is a widely used image processing technique to obtain composite information from two different kinds of image sources. This study proposes an image registration method based on moment information and surface distance, which improves the previous surface-based registration method. The proposed method ensures stable registration results with low registration error without being subject to the initial position and direction of the object. In the preprocessing step, the surface points of the object are extracted, and then moment information is computed based on the surface points. Moment information is matched prior to fine registration based on the surface distance, in order to ensure stable registration results even when the initial positions and directions of the objects are very different. Moreover, surface comer sampling algorithm has been used in extracting representative surface points of the image to overcome the limits of the existed random sampling or systematic sampling methods. The proposed method has been applied to brain MRI(Magnetic Resonance Imaging) and PET(Positron Emission Tomography), and its accuracy and stability were verified through registration error ratio and visual inspection of the 2D/3D registration result images.

다중 모달리티 영상정합은 서로 다른 성격의 두 영상의 중요정보를 결합하여 복합적 정보를 얻기 위해 널리 사용되는 영상처리 기법이다. 본 연구에서는 정합 대상 객체의 초기위치 및 방향에 종속적이지 않고, 낮은 정합오차 범위 내에서의 안정적인 정합을 지원하기 위하여 기존의 표면기반 정합 기법을 개선한 모멘트 정보 및 표면거리 기반의 정합 기법을 제시한다. 제안방법에서는 우선 정합대상객체의 표면 윤곽 점을 추출하고, 이를 기반으로 대상객체의 모멘트 정보를 추출하여, 표면거리 기반 상세 정합 이전에 모멘트 정보를 일치시키는 변환을 수행함으로써, 정합이전 대상객체의 위치 및 방향이 상이한 경우에 있어서도 정합이 안정적으로 수행되도록 한다. 또한 테스트 영상에 대한 표면 대표점 추출 시, 표면 코너추출법을 적용함으로써, 기존 표면 정보 기반 정합기법에서 일반적으로 사용하고 있는 무작위 샘플링 및 일정간격 샘플링에 의한 취약점을 보완한다. 본 논문에서 제안기법의 검증을 위하여 뇌 부위 자기공명단층영상(MRI)과 양자 방출 단층 촬영 영상(PET)을 적용하고, 정합오류율과 정합결과에 대한 2,3차원 가시화 영상의 육안평가를 통하여 정확성 및 안정성 측면을 검증한다.

Keywords

References

  1. J.B. Anotoine Maints, Max A. Viergever, 'A survey of Medical Image Registration,' Medical Image Analysis, Vol. 2.(1), 1-36: 1998 https://doi.org/10.1016/S1361-8415(01)80026-8
  2. Joseph V. Hajnal, Derek L.G. Hill, David J. Hawkes, 'Medical Image Registration,' . CRG Press, 2001
  3. Pietrzyk, U., Herholz, .K., Fink, G., Jacobs, A., Mielke, R, Slansky, I., Wurker, M., and Heis, W. (1994). An interactive technique for threedimensional image registration: validation for PET, SPECT,MRI and CT brain studies. Journal of nuclear medicine, 35, 2011-2018
  4. Ge, Y., Fitzpatrick, J. M., Votaw, J. R., Gadamsetty, S., Maciunas.R, J., Kessler, R. M., and Margolin, R. A. (1994). Retrospective registration of PET and MR brain images: an algorithm and its stereotactic validation. Journal of computer assisted tomography, 18(5), 800-810 https://doi.org/10.1097/00004728-199409000-00021
  5. Meyer, C. R, Leichtman, G. S., Brunberg, J. A, Wahl, R L., and Quint, L. E. (1995). Simultaneous. usage of homologous points, lines, and planes for optimal, 3-D, linear registration of multimodality imaging data. IEEE Transactions on medical imaging, 14(1), 1-11 https://doi.org/10.1109/42.370397
  6. Neelin, P., Crossman, L. Hawkes, D. L Ma, Y., and Evans, A. C. (1993). Validation of an MRV PET landmark registration method using 3D simulated PET images and point simulations. Computerized medical imaging and graphics, 17(4/5), 351-356 https://doi.org/10.1016/0895-6111(93)90028-L
  7. Evans, A. C., Marrett, S., Collins, L., and Peters, T. M. (1989). Anatomical-functional correlative analysis of the human brain using three dimensional imaging systems. In Schneider, R.H., Dwyer III, S.J, and Jost, R.G. (eds), Medical imaging: image processing, Vol. 1092, pp. 264-274, Bellingham, W A. SPIE press https://doi.org/10.1117/12.953267
  8. Evans, A. C., Collins, D. L., Neelin, P., and Marrett, T. S. (1996). Correlative analysis of three-dimensional brain images. In Taylor, R H., Lavallee, S., Burdea, G. C., and Mosges, R.(eds), Computer-integrated surgery, Technology and clinical applications, chapter 6, pp. 99-114. MIT Press, Cambridge, MA
  9. Evans, A. C., Marrett, S., Torrescorzo, L. Ku, S., and Collins, L. (1991). MRI-PET correlation in three dimensions using a volume of interest (VOI) atlas. Journal of cerebral blood flow and metabolism, 11, A69-A78 https://doi.org/10.1038/jcbfm.1991.40
  10. Maguire, G. Q., Noz, M., Rusinek, H., Jaeger, L. Kramer, E. L., Sanger, J.J. and Smith, G. (1991). Graphics applied to medical image registration. IEEE Computer graphics and applications, 11(2), 20-28 https://doi.org/10.1109/38.75587
  11. Wahl, R. L., Quint, L. E., Cieslak, R.D., Aisen, A. M., Koeppe, R. A., and Meyer, C. R (1993). 'anametabolic' tumor imaging: fusion of FDG PET with CT or MRl to localize foci of increased activity. Journal of nuclear medicine, 34, 1190-1197
  12. Chen, C., Pelizzari, C. A., Chen, G. T. Y., Cooper, M. D., and Levin, D. N. (1987). Image analysis of PET data with the aid of CT and MR images. In Information processing in medical imaging, pp. 601-611
  13. Levin, D. N., Pelizzari, C. A., Chen, G. T. Y., Chen, C.T., and Cooper, M. D. (1988). Retrospective geometric correlation of MR, CT, and PET images. Radiology, 169(3), 817-823
  14. Staib, L. H. and Xianzhang, L. (1994). Intermodality 3D medical image registration with global search. In IEEE workshop on biomedical image analysis, pp. 225-234, Los Alamitos, CA. IEEE computer society press https://doi.org/10.1109/BIA.1994.315849
  15. Turkington, T. G., Hoffman, J. M., Jaszczak, R. J. MacFaII, J. R., Harris, C. C., Kilts, C. D., Pelizzari, C. A., and Coleman, R. E. (1995). Accuracy of surface fit registration for PET and MR brain images using full and incomplete brain surfaces. Journal of computer assisted tomography, 19(1), 117-124 https://doi.org/10.1097/00004728-199501000-00022
  16. Turkington, T. G., jaszczak, R J., Pelizzari, C. A., Harris, C., MacFall, J. R, M., Hoffman J., and Coleman, R. E. (1993). Accuracy of registration of PET, SPECT and MR images of a brain phantom. Journal of nuclear medicine, 34, 1587-1594
  17. Tsui, W., Rusinek, H., van Gelder, P., and Lebedev, S. (1993). Fast surface-fitting algorithm for 3-D image registration. In Loew, M. H. (ed.), Medical imaging: image processing, Vol. 1898, pp. 14-23, Bellingham, WA. SPlE Press https://doi.org/10.1117/12.154504
  18. Jiang, H., Robb, R. A., and Holton, K. S. (1992). A new approach to 3-D registration of multi~ modality medical images by surface matching. In Visualization in biomedical computing, Vol. 1808, pp. 196-213, Bellingham, W A. SPIE press https://doi.org/10.1117/12.131078
  19. Ardekani, B. A., Braun, M., Hutton, B. F., Kanno, I., and Ida, H. (1995). A fully automatic multimodality image registration algorithm. Journal of computer assisted tomography, 19(4), 615-623 https://doi.org/10.1097/00004728-199507000-00022
  20. Ardekani, B. A., Braun, M., Kanno, I., and Hutton, B. F. (1994). Automatic detection of intradural spaces in MR images. Journal of computer assisted tomography, 18(6), 963-969 https://doi.org/10.1097/00004728-199411000-00022
  21. Kruggel, F. and Bartenstein, P. (1995). Automatical registration of brain volume datasets. In Bizais, Y., Barillot, C., and eli Paola, R(eds), Information processing in medical imaging, pp. 389-390, Kluwer
  22. Andersson, J. L. R (1995). A rapid and accurate method to realign PET scans utilizing image edge information. Journal of nuclear medicine, 36, 657-669
  23. Miller, M. I., Christensen, G. E., Amit, Y. A., and Grenander, U. (1993). Mathematical textbook of deformable neuroanatomies. In National academy of sciences, Vol. 90 of Medical sciences, pp. 11944-11948 https://doi.org/10.1073/pnas.90.24.11944
  24. Woods, RP., Maziotta, J.C., and Cherry, S.H. (1993). MRI-PET registration with automated algorithm. journal of computer assisted tomography, 17(4), 536-546 https://doi.org/10.1097/00004728-199307000-00004
  25. Collignon, A., Maes, F., Delaere, D., Vandermeulen, D., Suetens, P., and Marchal, G. (1995). Automated multimodality image registration using information theory. In Bizais, Y. and Barillot, C. (eds), Information Processing in Medical Imaging, pp, 263-274. Kluwer Academic Publishers, Dordrecht
  26. Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., and Suetens, P. (1996). Multi-modality image registration by maximization of mutual information. In Mathematical methods in biomedical image analysis, pp. 14-22, Los Alamitos, CA. IEEE computer society press
  27. Wells III, W. M., Viola, P., Atsumi, H., Nakajima, S., and Kikinis, R. (1996). Multi-modal volume registration by maximization of mutual information. Medical image analysis, 1. In press https://doi.org/10.1016/S1361-8415(01)80004-9
  28. Wells III, W. M., Viola, P., and Kikinis, R. (1995). Multi-modal volume registration by maximization of mutual information. In Medical robotics and computer assisted surgery, pp. 55-62. Wiley
  29. Rubinstein, R., Karger, H., Pietrzyk, U., Siegal, T., Gomori, J. M., and Chisin, R. (1996). Use of 201thallium brain SPECT, image registration, and semi-quantitative analysis in the follow-up of brain tumors. European journal of radiology, 21, 188-195 https://doi.org/10.1016/0720-048X(95)00726-7
  30. Malison, R. T., Miller, E. G., Greene, R., McCarthy, G., Charney, D. S., and Innis, R. B. (1993). Computer-assisted coregistration of multislice SPECT and MR brain images by fixed external fiducials. Journal of computer assisted tomography, 17(6), 952-960 https://doi.org/10.1097/00004728-199311000-00018
  31. Maintz, J. B. A., van den Elsen, P. A., and Viergever, M. A. (1996). Registration of SPECT and MR brain images using a fuzzy surface. In Loew, M. H. and Hanson, K. M. (eds), Medical Imaging: Image processing, Vol. 2710, pp, 821-829, Bellingham, W A SPIE https://doi.org/10.1117/12.237988
  32. Peria, O., Franc. ois- Joubert, A, Lavallee, S., Champleboux, G., Cinquin, P., and Grand, S. (1994). Accurate registration of SPECT and MR brain images of patients suffering from epilepsy or tumor. In Medical robotics and computer assisted surgery, pp. 58-62
  33. Rechard L. Burden, J. Douglas Faires, 'Numerical analysis,' Brooks/Cole Publishing compeny, 1997
  34. Otsu, N., 'A threshold selection method from gray-level histograms,' IEEE Transactions on Systems, Man, and Cybernetics, vol. 9, no. 1, pp. 62-66, 1979 https://doi.org/10.1109/TSMC.1979.4310076
  35. Alan watt, Fabio Policarpo, 'The Computer Image,' Addison Wesley, 1998
  36. Rafael C. Gonzalez, Richard E. Woods., 'Digital Image Processing,' Addison-Wesley, Publishing Company, Inc., 1993
  37. 김희승, '영상인식', 생능출판사, 1993
  38. Ioannis Pitas, 'Digital Image Processing Algorithms,' Prentice Hall, 1995
  39. Dana H. Ballard, 'Christopher M. Brown, Computer vision,' Prentice Hall Inc., 1982
  40. Milan Sonka, J. Michael Fitzpatrick, 'Handbook of Medical Imaging,' SPIE Press, 2000
  41. H. Freeman and L. S. Davis, 'A comer finding algorithm for chain-coded curves,' IEEE Trans. Comput. 26, 297-303, 1977 https://doi.org/10.1109/TC.1977.1674825