Abstract
The results of the combustion performance tests of gas generator which supplies hot gas into the turbine of turbo-pump for liquid rocket engine and uses LOx and kerosene as propellant are described. The gas generator consists of a injector head with F-O-F impinging injector, a water cooled combustion chamber, a gas torch igniter, a turbulence ring and an instrument ring. The effect of turbulence ring and combustion chamber length on performance of gas generator are investigated. The ignition and combustion at design point are stable and the pressure and gas temperature at gas generator exit meets the target. The turbulence ring installed at middle of chamber effectively mixes hot gas with cold gas and the effect of residence time of hot gas in gas generator on combustion efficiency is small. Test results show that the main parameter controlling the gas temperature at gas generator exit is overall O/F ratio.
본 논문에서는 액체로켓엔진용 160 kW급 터보펌프의 터빈을 구동하고, 액체산소와 케로신을 추진제로 사용하는 연료 과잉 가스발생기의 설계점 연소성능시험 결과에 대해 논의하였다. 충돌형 F-O-F 분사기로 구성된 헤드부, 물냉각 채널 연소실, torch igniter, turbulence ring 그리고 측정 링을 갖는 가스발생기에 대해 기술하였고, 설계점에서의 연소시험 및 turbulence ring 장착여부. 연소실 길이 변화에 따른 연소시험의 결과들에 대해 기술하였다. 연소시험 결과 가스발생기는 설계점에서 안정된 작동성을 보여주었고. 연소압력 및 온도 등의 성능은 예측치에 근접하는 결과였다. Turbulence ring은 출구에서의 가스온도를 균일하게 분포시켜 효과적인 혼합 장치임을 보여 주었고, 4∼6msec 정도에서의 연소가스 잔류시간은 연소효율에 큰 영향을 주지 않았다. 가스발생기 출구에서의 온도는 공급되는 추진제의 O/F ratio에 따라 매우 민감하게 변화하였다.