Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구

  • Published : 2004.05.01

Abstract

Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Keywords

References

  1. 박지훈, '고속 데이터 통신을 위한 전력선 특성에 관한 연구, 석사 논문, 서울 대학교, 1999
  2. D. A. Pitt, 'Residential communications.' The Hewlett-packard Journal, Dec, 1997
  3. E.Yavuz, 'Modeling of Power Lines for Digital Communications,' Proceedings of the Power-Line Communications and Its Applications pp.161-168, March, 2000
  4. 대한전자공학회, '홈 네트워킹 기술 워크샵,' July 2002
  5. 김수관, 전력선 데이터 통신을 위한 적응 채널 추정 기법에 관한 연구,' 석사 논문, 서울 대학교, 2001
  6. J.W. Lechlider, 'Line analysis for digital subscriber Lines,' IEEE Commun, pp.25-32, Sept, 1989
  7. S.Tsuzuki, 'Measurement of Japanese Indoor Power-line Channel,' Proceedings of the Power-Line Communications and Its Applications pp.79-84, April, 2001
  8. S.Tsuzuki, 'An Estimation Method of the Transger Function of Indoor Power-Line Channels for Japanese House,' Proceedings of the Power-Line Communications and Its Applications pp.55-59, March, 2002
  9. 이상신, '전력선 통신을 위한 CPSEK 모뎀에 관한 연구,' 석사 논문, 서울 대학교, 2000.
  10. 박건수 외, '전력전송공학', 청문각, 1992
  11. Seon-Hyo Kim, A Characteristic Analysis of the Wire to Wire to Ground Channel for PLC on 22.9kV Medium Volrage Power line,' The Journal of the Korean Institute of Communication Sciences Vol 27 No 9B, pp.886-894, 2002
  12. Manfred Zimmermann, Klaus Dostert, 'A Multo path-Signal Propagation Model for the power line Channels at High Frequency Range', Proceedings of the Power-Line Communications and Its Applications, pp.45-51, 1999
  13. J.A.Malack, 'RF impedance of United States and European power lines', IEEE Trans. Electromagnetic Compatibility, pp.36-38, Feb.1976 https://doi.org/10.1109/TEMC.1976.303453
  14. R.M.Vlines,'Impedance of the residential power distribution circuit,' IEEE Trans. Electromagnetic Compatibility, vol.EMC-27, no. 1, pp.6-12, Feb. 1985 https://doi.org/10.1109/TEMC.1985.304239
  15. M.Tanaka, 'High frequency noise power spectrum, impedance and transmission loss of powerline in Japen on intrabuilding power line communications', IEEE Trans Comsumer Electronics, vol. 34, no.2, pp.321-326, May. 1988 https://doi.org/10.1109/30.2948
  16. J.R. Nicholson, 'RF Impedance of Power-Lines and Line Impedance Stabilization Network in Conducted Interference Measurements', IEEE Transactions on Electromagnetic Compatibility, vol.1, EMC-12, No.2, pp.84-86, May, 1973 https://doi.org/10.1109/TEMC.1973.303254
  17. O.G.Houijen, 'A Channel Model for the Low Voltage Power-Line Channel Measurement and Simulation Results', Proceedings of the Power-Line Communication and Its Applications pp.51-56, April, 1997
  18. P.J. Kwasniok, 'Techique for Measurement of Power Line Impedance in the Frequency Range From 500KHz to 500KHz,' IEEE Transactions on Electromagnetic Compatibility, vol.35, No.1, pp.87-90, Feb 1993 https://doi.org/10.1109/15.249399
  19. David M. Pozar, 'Microwave Engineeting', Addison Wesley, 1998
  20. Jae-Jo Lee, 'Development of PLC subscriber networks on the Medium VolragePower Grid', International Conference on Electrical Engineering, pp. 1935-19, 2002
  21. Carlos Romero Perez, 'Experimental Methods to Model Power Line Communications Equipment', I+DT Group of Sainco
  22. Jerry Sevick,'Transmission Line Transformers', Published by the American Radio Relay League, 1991
  23. Soon-Won kwon,'A Study for the Network Performance of Power-line Communication Subscriber Network using Medium Voltage Distribution Lines', 한국 통신학회 추계 학술대회, 2002
  24. Experimental Methods to Model Power Line Communications Equipment Carlos Romero Perez
  25. Transmission Line Transformers Jerry Sevick
  26. 한국 통신학회 추계 학술대회 A Study for the Network Performance of Power-line Communication Subscriber Network using Medium Voltage Distribution Lines Soon-Won kwon