RLSE알고리즘을 이용한 원격 정전용량형 습도 센서 시스템

Passive Telemetry Capacitive Humidity Sensor System using RLSE Algorithm

  • 발행 : 2004.05.01

초록

In this paper, passive telemetry capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome the problem like power limits and complications that general passive telemetry sensor system including IC chip has, the principle of inductive coupling is applied to model the sensor system. Specially. by applying the forgetting factor we show that the accuracy of its estimation can be improved even in the case of time varying parameter and also the convergence time can be reduced.

키워드

참고문헌

  1. A Recursive Frequency Tracking Method for Passive Telemetry Sensors K.J.Cho;H. Harry Asada
  2. Korea Fuzzy Logic and Intelligent Systems Society v.1 no.1 Passive Telemetry Sensor System using Recursive Least Squares Estimation K.Y.Kim;J.T.Lee
  3. Neuro-Fuzzy and Soft Computing J.S.R.Jang;C.T.Sun;E.Mizutani
  4. The 14th IEEE International Conference on MEMS A Passive Wireless Integrated Humidty Sensor Timothy J. Harpster;Brain Stark;Khalil Najafi
  5. Microelectronic Engineering Research Conference Performance of Polyamide-Based Humidity Sensor Takeharu Suzuki
  6. Adaptive Control K.J.Astrom;B.Wittenmark