DOI QR코드

DOI QR Code

Evaluation of Capacity Spectrum Methods for Estimating the Peak Inelastic Responses

최대 비탄성 변위 응답 예측을 위한 기존 능력스펙트럼법들의 유효성 평가 및 비교

  • Published : 2004.04.01

Abstract

In the capacity spectrum method(CSM) using a linear response spectrum, the peak response of an inelastic system under a given earthquake load is estimated transforming the system into the equivalent elastic one. The CSM for estimating the peak inelastic response is evaluated in this paper. The equivalent period and damping ratio are calculated using the ATC-40, G lkan, Kowalsky, and Iwan methods, and the performance points are obtained according to the procedure B of ATC-40. Analysis results indicate that the ATC-40 method generally underestimates the peak response resulting in the unsafe design, while the G lkan and Kowalsky methods overestimate the responses. The Iwan method produces the values between those by the ATC-40 method and the G lkan and Kowalsky methods, and estimates the responses relatively closer to the exact ones. Further, it is found that the Kowalsky method gives the negative equivalent damping ratios depending on the hardening ratios, and thereby can not be used to estimate the responses in some cases.

탄성응답스펙트럼을 사용하는 능력스펙트럼법은 비선형 시스템을 등가의 선형시스템으로 치환하여 주어진 지진 하중에 대한 구조물의 최대 비선형 거동을 예측한다. 본 연구의 목적은 이러한 능력스펙트럼법들의 정확성을 검증하고, 예측 특성을 비교하는 것이다. 이를 위해, ATC-40, G lkan, Kowalsky, 그리고 Iwan이 제시한 방법을 이용하여 등가주기와 등가감쇠비를 산정한 후, ATC-40에서 제시한 절차B에 따라 성능점을 산정 하였다. 전반적으로 ATC-40 방범은 구조물의 응답을 과소 평가하여 안전하지 못한 설계결과를 가져 올 수 있으며, G lkan과 Kowalsky의 방법은 과대 평가하는 경향을 가지고 있다. Iwan이 제시한 방법은 ATC-40 방법과 G lkan과 Kowalsky 방법의 중간 값을 예측함으로써, 비교적 정확한 값에 가까운 최대 변위를 산출하였다. 그리고, Kowalsky 방법은 항복 후 강성비에 따라 등가감쇠비를 음수로 산정함으로써 예측 값을 제시하지 못하는 경우가 있음을 확인하였다.

Keywords

References

  1. 민경원, 김형섭, "지진하중을 받는 구조물의 성능에 기초한 마찰감쇠기 설계", 한국지진공학회 논문집, 제7권, 제6호, 2003. https://doi.org/10.5000/EESK.2003.7.6.017
  2. 김진구, 최현훈, "능력스펙트럼법을 이용한 점성 감쇠기의 적정 감쇠비 산정", 한국지진공학회 논문집, 제5권, 제1호, 2001, pp. 45-52.
  3. Whittaker, A., Constantinou, M., and Tsopelas, P., "Displacement estimates for performance-based seismic design," Journal of Structural Engineering ASCE, Vol. 124, No. 8, 1988, pp. 905-912. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:8(905)
  4. Applied Technology Council, "Seismic evaluation and retrofit of concrete buildings," Report ATC-40, Applied Technology Council, Redwood City, California, 1996.
  5. Federal Emergency Management Agency, "NEHRP guidelines for the seismic rehabilitation of buildings," Reports FEMA-273(Guidelines) and 274(Commentary), Federal Emergency Management Agency, Washington, DC, 1997.
  6. Rosenblueth, E. and Herrera, I., "On a kind of hysteretic damping," Journal of Engineering Mechanics Division ASCE, Vol. 90, 1964, pp. 37-48.
  7. Gulkan, P. and Sozen, M., "Inelastic response of reinforced concrete structures to earthquakes motions," ACI Journal, Vol. 71, 1974, pp. 604-610.
  8. Kowalsky, M., Priestley, M. J. N., and Mac Rae, G. A., "Displacement-based design of RC bridge columns in seismic regions," Earthquake Engineering and Structural Dynamics, Vol. 24, 1995, pp. 1623-1643. https://doi.org/10.1002/eqe.4290241206
  9. Iwan, W. D. and Gates, N. C., "The effective period and damping of a class of hysteretic structures," Earthquake Engineering and Structural Dynamics, Vol. 7, 1979, pp. 199-211. https://doi.org/10.1002/eqe.4290070302
  10. Miranda, E. and Ruiz-García, J., "Evaluation of approximate methods to estimate maximum inelastic displacement demands," Earthquake Engineering and Structural Dynamics, Vol. 31, 2001, pp. 561-582. https://doi.org/10.1002/eqe.144
  11. 송종걸, "역량스펙트럼 방법을 이용한 교량의 내진성능평가," 대한토목학회 논문집, Vol. 22, No. 5-A, 2001, pp. 1011-1021.