Abstract
In order to investigate the performance of carbon dioxide PSA over zeolite adsorbent, the present study showed results of isotherm measurement, cyclic operation of 3-bed apparatus, and the corresponding numerical simulation. The experiment data of bed temperature, purity, recovery were matched well with that of numerical simulation. Purity of both gas and adsorbent phase increased rapidly with rinse rate but the degree of increase was retarded for large rinse rate The total amount of adsorbed increased only 10% even if rinse rate was enlarged to 4 times. Optimal rinse rate was 7N㎥/hr in this study. The heating rinse led to augments in recovery and productivity, possibly thanks to ease of description resulting from increased volumetric rinse rate and temperature rise in the column.