초록
It is important to mechanical properties of dielectric paper and cable to optimum electrical insulation design of HTS cable, because the cable has experience of mechanical stress, such as tensile stress, bending stress. Also, it is operated at cryogenic temperature. From the results, it was observed that the tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen is decreased. Because PPLP was deteriorated by microcrack and tensile strain. According as bending radius multiple is decrease, the ac and impulse breakdown stress of mini-model cable is sharply decreased.