Analysis of Geophysical and Geotechnical SPT Data for the Safety Evaluation of Fill Dam

필댐 안정성 평가를 위한 물리탐사와 SPT 자료의 분석


Abstract

Electrical resistivity survey is widely used to investigate the stability of center-core type fill dam against the seepage phenomenon. In this study, we analyze the resistivity information obtained on a earth fill dam and compare it with the geotechnical SPT result. The analysis shows that the zones showing low resistivity value generally have low N value. However, some zones with high resistivity pattern do not accompany the increase of N value, and even showing low N value. These results imply that the direct identification of resistivity value to the real status of the core material of fill dam is impossible, and a highly resistive zone may be in serious status due to the effect increasing the resistivity value by the piping condition. Therefore, multiple exploration should be planned to reduce the uncertainty in application of geophysical methods to dam safety evaluation.

중심코아형 필댐(Fill Dam)의 침투수에 대한 안정성 평가에 널리 적용되고 있는 전기비저항 탐사 해석의 이해를 증진하기 위해 시추과정에서 얻어진 표준관입시험 결과를 비저항 분포자료와 비교 분석하였다 그 결과 일반적으로 비저항 값이 낮은 곳에서 표준관입시험의 값도 낮은 경향을 보이고 있었으나 비저항이 높은 곳에서는 값의 분포가 동일한 경향성을 보이지 않거나 오히려 낮게 나타나는 구역도 관찰되었다 또한 일부 구역에서 비저항이 낮은 경우 에 값이 높게 나타나는 경우도 있었는데 이는 전기비저항 조사의 특성상 직하부의 효과뿐만 아니라 사면부의 효과가 포함되어 나타난 것으로 보인다 따라서 비저항이 단순히 낮다고 해서 코아부의 지수 능력에 문제가 있다고 판단하기는 매우 어려우며 오히려 비저항이 높은 지점에서 파이핑에 의한 과도 침투수를 유발할 수 있는 가능성을 확인하였다 이와 같은 비저항 분포 해석의 불확실성을 감소시키기 위해서는 동반 탐사를 통해서 이상대역을 확인하는 과정이 필요하며 장기간의 모니터링과 수위 변화에 따른 지속적인 조사가 필요하다 또한 비저항 콘(resistivity cone)과 같은 장비를 이용하여 현장 조건을 유지한 상태에서의 하부 비저항 구조를 이해할 필요가 있다.