Abstract
The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.
이 연구는 self-etching primer와 adhesive를 사용하여 법랑질 표면에 교정용 브라켓을 접착할 때 수분과 타액, 그리고 혈액에 의한 오염이 브라켓의 전단결합강도에 어떤 영향을 미치는지 알아보고자 시행되었다. 96개의 발거된 치아를 4개의 군으로 나누어서 self-etching primer와 adhesive를 사용하여 다음의 4가지 방법에 따라 교정용 브라켓을 접착하였다 첫 번째 군은 치면을 건조시킨 상태에서 부착하였고 두 번째, 세 번째, 네 번째 군은 각각 증류수, 인공타액. 혈액을 적용한 후 브라켓을 접착하였다 각 시편의 전단결합강도를 측정하였고 debonding 후에 브라켓과 치아 표면은 stereomicroscope을 사용하여 관찰하였다. 각 군에서 4개씩의 시편을 선택하여 표면처리된 법랑질 표면과 접착계면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 건조군과 증류수군의 전단결합강도는 각각 $15.22{\pm}2.86$ MPa과 $160.20{\pm}3.85MPa$로 혈액군의 전단결합강도$(12.50{\pm}2.94MPa)$보다 높았다.(P<0.05). 건조군과 증류수군, 그리고 인공타액군간에는 전단결합강도에 통계적 차이가 없었다(p>0.05). 혈액군은 다른군에 비해서 debonding 후 법랑질 표면에 잔류한 레진의 양이 더 적었다.(p<0.06). self-etching primer로 처리된 치면의 주사전자현미경 소견에서 건조군과 증류수군의 치면에서는 인공타액군과 혈액군에 비해서 더욱 뚜렷한 산부식 구조를 볼 수 있었다. 이상의 결과로서 self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 수분이나 타액의 오염은 결합력에 거의 영향을 미치지 않음을 알 수 있으며. 혈액으로 오염시에는 결합력에 영향을 미치지만. 임상적으로 유용한 최소 결합강도(5.9-7.8 MPa) 이상을 보이고 있음을 알 수 있었다.