Interference and Re-Inflow of Contaminated Air in Successive Tunnel

연속터널에서의 오염물질 재유입 및 환기영향평가

  • Published : 2003.06.01

Abstract

Recently, there are many cases in the roadway design for successive tunnel with small distance between two tunnels. In this case, the degree of interference for successive tunnels is a significant consideration in the design of ventilation systems. Also, Re-inflows of contaminated air in successive tunnel make serious ventilation problems in case of fire accident in the tunnel. In this study, for successive tunnels in Donghae highway project, the concentration of contaminant such as CO, NOx and Smoke were calculated by numerical analysis using 1D and 3D-CFD analysis. And, the rate of re-inflow at the portals of successive tunnel according to the direction of wind were analysed.

최근 도로설계시 두 개의 터널이 짧은 거리로 계속적으로 존재하는 연속터널에 대한 설계사례가 증가하고 있다. 이러한 경우에 있어, 한 터널내에서 발생한 오염물질은 다른 터널로 재유입하여 터널환기 시스템에 중대한 영향을 미치게 되므로, 이에 대한 적절한 환기검토가 수행되어야 한다. 본 연구에서는 동해 고속도로 설계시 나타난 연속터널을 대상으로 하여 1차원 터널내 오염농도 해석 및 3차원 CFD 해석 프로그램을 사용하여 터널내 오염농도의 거동 및 터널 갱구부 주변의 오염물질의 재유입 여부를 분석하여, 연속터널에 대한 터널내 외부유동에 대한 환기영향을 검증하였다. 이를 위하여 해당지역인 속초지방의 기상데이터를 분석하고, 기상조건에 따른 터널내부의 공기환경을 검토하였으며, 3차원 시뮬레이션을 통하여 각각의 터널에 대한 재유입 여부 및 재유입율을 분석하였다.