An Experimental Study on Laminar Flow Temperature Using Thermo-sensitive Liquid Crystal

감온액정을 이용한 층류유동의 온도장에 관한 실험적 연구

  • 장태현 (경남대학교 기계자동화공학부)
  • Received : 2003.08.11
  • Accepted : 2003.11.20
  • Published : 2003.11.30

Abstract

An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the temperature field in a two-dimensional cross section of fluid flow. This study found the temperature distribution for Re =900~1,500 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for temperature measurement and liquid crystal is used for heat transfer experiments in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

Keywords

Acknowledgement

Supported by : 경남대학교