Abstract
Generally, application of steel pipe pile as deep foundation member needs special requirement for the connection method between steel pipe pile and concrete footing. Even though two types of connection method are suggested in the related specification, type B-method is provident. To investigate real structural behavior of type B connection, several load tests are done with carefully designed experimental system. The purpose of this experiment is mainly focused on the understanding of actual behavior which can be predicted by design theory. At this research stage, vertical and lateral loading test are done for three types of specimen to review stress concentration, formation and behavior of imaginary RC column in the footing and effect of non-slip device installed in the steel pipe pile. The load resistance mechanism in these specific connection method is predicted based on both experimental results. The three-dimensional finite element modeling is also done for the purpose of comparison between numerical and experimental result. With all the results gained from experiment the structural behavior of imaginary RC column in the design concept is confirmed. The role of non-slip device is very important and it affects the resistance capacity with help of composite action of concrete and steel pipe pile.
최근 말뚝기초 공법으로서 강관말뚝의 활용이 토목 및 건축 분야에서 증대됨에 따라 이종의 재질을 가진 강관 말뚝과 콘크리트 확대 기초의 연결방법에 대한 기술개발 및 실제거동 파악에 대한 관심이 매우 높아지고 있다. 연결부에 대한 국내 시방서는 두 가지(A, B-type) 연결방법을 제시하고 있지만 실제적으로는 B-type 방법이 주로 활용되고 있는 상황이다. 본 논문에서는 강관 말뚝의 B-type 연결방법의 구조거동을 파악하기 위하여 말뚝에 작용하는 대표적인 하중인 연직하중에 대하여 3종류와 수평 하중에 대하여 두 종류의 실험체에 대한 재하시험을 실시하였다. 또한 재하실험 결과값에 대한 비교 분석을 위하여 3차원 유한 요소해석을 수행하였다. 실험과 수치해석 결과를 비교 분석한 바 현재 강관 말뚝 연결부의 설계법으로 적용되고 있는 가상 철근 콘크리트 기둥의 거동을 확인하였다. 또한 콘크리트 확대기초에 작용하는 하중을 강관으로 전달하기 위하여 사용되는 미끌림 방지턱의 역할과 이러한 방지턱이 강관과 콘크리트의 합성거동에 미치는 영향을 확인하였다. 본 연구를 통하여 향후 합리적인 강관 말뚝 연결부에 대한 설계 방법 및 기준을 정립함에 있어 기초 연구자료와 강관 말뚝 연결부의 구조거동을 파악하기 위한 실험방법을 제시하였다.