References
- Amman, D. : Ion-selective microelectrodes, principles, design and application, Springer-Verlag Germany (1986)
- Spichiger-Killer, U. E. : Chemical sensors and biochemical sensors for medical and biological applications. Wiley-VCH (1998)
- Ali Taher, M. : Preconcentration of trace nickel with the ion pair of disodium 1-nitroso-2-naphthol-3,6-disulfonate and tetradecyldimethylbenzylammonium chloride on microcrys-talıine naphthalene or by the column method and determina-tion by third derivative spectrophotometry. Talanta 50, 559 (1999) https://doi.org/10.1016/S0039-9140(99)00153-8
- Ali Taher, M. : Derivative spectrophotometric determination of cobalt in alloys and biological samples after preconcentration with the ion pair of disodium 1-nitroso-2-naphthol-3,6disulfonate and tetradecyldimethylbenzylammonium choloride on microcystalline naphthalene or column method. Anal. Sci. 16, 501 (2000) https://doi.org/10.2116/analsci.16.501
- Liu, X. and Fang, Z. : Flame atomic absorption spectrometric determination of cobalt in biological materials using a flow-injection system with on-line preconcentration by ion-pair adsorption. Anal. Chim. Acta 316, 329 (1995)
- Zhang, L. and Terada, K. : Spectrophotometric Determination of cobalt (II) in water after preconcentration by sorption of its nitroso R complex with poly(chlorotrifluoroethylene)resin. Anal. Sci. 10, 161 (1994) https://doi.org/10.2116/analsci.10.161
- Craggs, A., Moody, G. J., Thomas, J. D. R. : PVC matrix membrane ion-selective electrodes. J. Chem. Ed. 51, 8 (1974)
- Eugster, R., Rosatzin, T., Rusterholz, B., Aebersold, B., Pedrazza, U., Ruegg, D., Schmid, A., Spichiger, U. E. and Simon, W. : Plasticizers for liquid polymeric membrane of ion-selective chemical sensors. Anal. Chim. Acta 289, 1 (1994)
- Suzuki, H., Nakagawa, H., Mifune, M. and Saito, Y. : A widely applicable electrode sensitive to basic drugs based on poly(vinyl chloride) membrane plasticized with tricresyl phosphate. Chem. Pharm. Bull. 41, 1123 (1993)
- Takashi, M., Toshihiko, I., Shin-ichi, w., Kunishige, H. and Yasukazu, A. : Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly(vinyl chloride) membrane electrode with no added ion-exchanger. Anal. Sci. 16, 383 (2000) https://doi.org/10.2116/analsci.16.383
- Cosofret, V. V. and Buck, R. P. : Pharmaceutical application of membrane sensor. CRC press. U.S.A. (1992)
- Ahn, M. K., Oh, W. J., Lee, E. K., Lee, J. Y., Jung, M. M. and Hur, M. H. : Determination of acidic drug with ISEs using ternary complex of metal-di-2-pyridyl ketone oxim-acidic drug as ion-exchanger. Yakhak Hoeji 46, 320 (2000)
- Puzanowska-Tarasiewicz, H. and Karpinska, J. : Determination of phenothiazines in drugs. Pharmazie 45, 887 (1992)
- Karpinska, J., Starczewska, B. and Puzanowsk-Tarasiewicz, H. : Analytical properties of 2,10-disubstituted phenothiazine derivatives. Anal. Sci. 12, 161 (1996) https://doi.org/10.2116/analsci.12.161
- Mostafa, G. A. E. : PVC matrix membrane sensor for potentiometric determination of cetylpyridium chloride. Anal. Sci. 17, 1043 (2001) https://doi.org/10.2116/analsci.17.1043