Design Case Study of Geosynthetic Reinforced Segmental Retaining Walls in Tiered Configuration

다단식 보강토 옹벽의 설계 사례 연구

  • Published : 2003.12.01

Abstract

This paper presents the results of design case study on soil-reinforced segmental retaining walls in tiered configuration. Six different field walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was additionally performed based on the method recommended by FHWA design guidelines. The results indicate that the as-built designs of some of the walls examined do not meet the minimum factors of safety for the external and Internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

본 논문에서는 계단식 형태로 시공되는 블록식 보강토 옹벽의 설계사례에 대한 검토 내용을 다루었다. 이를 위해 6개 현장에 대한 설계관련 자료를 수집하여 현재 통용되고 있는 한계평형기법 기반의 설계기준에 부합하는지 여부를 분석하였으며 이와 아울러 계단식 옹벽에서 중요한 검토 항목인 복합파괴 .유형에 대한 사면안정성 검토를 FHWA 설계기준에 근거하여 수행하였다. 검토결과 몇몇 옹벽은 현 설계기준에서 요구하는 내적 및 외적 안정성을 만족하지 않는 것으로 나타났으며 복합파괴에 대한 안정성 또한 만족하지 않는 것으로 나타났다. 본 연구에서 얻어진 결과를 토대로 실무적용시 유의 사항을 다루었다.

Keywords

References

  1. Design Manual for Segmental Retaining Walls (2nd Ed.) NCMA
  2. FHWA Demonstration Project 82, FHWA-SA-96-071 Mechanically Stabilized Earth Walls and Reinforced Soil Slopes, Design and Construction Guidelines FHWA