Abstract
Several geophysical surveys(electrical resistivity, electromagnetic, seismic refraction, CPR) were conducted to primarily investigate the gallery and the geomembrane at an abandoned mine(Imcheon mine). The subsurface structure mapped from seismic refraction survey mainly consists of three velocity layers(>1000 m/s, 1000∼2000 m/s,<2000 m/s). Top of the bedrock, whose velocities exceed 2000 m/s, appears to be at depth of 7.5∼10m. Higher resistivities (of ten thousands-hundred of thousands ohm-m) are interpreted to be associated with a open(cavities) gallery. The events at depth of approximately 0.5∼0.7m in GPR sections are probably caused by high-density-poly-ethylene geomembrane. Taking into consideration of the differences in the spatial resolution between georadar and electrical surveys, the events of geomembrane correspond to the top of the high resistivities at depth of about 2m. The segments, characterized with the higher conductivities in the electromagnetic data and the lower resistivities in the electrical resistivity data, are probably associated with surface water or tear zone of geomembrane.
충남 부여의 임천 폐광산의 지하갱도와 폐광석 적치장의 인공차수막의 차수효과를 탐지하기 위해 각종 지구물리탐사 (전기비저항, 전자탐사, 탄성파굴절법, 지반투과레이다)를 실시하였다. 탄성파굴절법탐사 역산결과 주요 굴절면의 속도는 1000m/s 이하, 1000∼2000m/s, 2000m/s 이상의 3개 층으로 구분되며, 이중에서 2000m/s 이상의 속도를 갖는 기반암은 주로 7.5-10m사이에 분포하는 것으로 나타났다. 전기비저항탐사자료에서 수만∼수십만 ohm-m의 높은 전기비저항값은 지하갱도에 의한 효과로 해석된다. 또한 폐광석 적치장의 산성광산배수 발생을 억제하기 위해 설치한 인공차수막은 지반투과레이다탐사에서 0.5∼0.7m 사이에서 일관적으로 나타나는 이벤트와 대비되는데 이것은 전기비저항탐사 결과에서는 전극간격의 분해능을 고려할 때 천부 2m 이내에서 연속적으로 나타나는 고비저항 이상대와 관련된 것으로 해석된다. 전기비저항탐사와 전자탐사 결과 특정구간에서 낮은 전기비저항과 높은 전기전도도 값은 지표수의 침수 또는 인공차수막의 차수효과가 일부 저하된 것으로 해석된다.