Channel Design of Decanter-Type Centrifuge (II) - Particles' Sediment and the Bowl Length

원심분리기의 채널 설계(II) - 입자의 침강문제와 보울 길이

  • 서용권 (동아대학교 기계산업시스템공학부)
  • Published : 2003.11.01

Abstract

In this paper, based on the concept of solid particles' sediment problem the working formula determining the bowl length of a Decanter-type centrifuge were derived. Assuming that particles are uniformly distributed along the vertical line of the liquid inlet position, it was possible to derive a constant value k used for determining the bowl length. It was shown from the sample calculations that the bowl length should be increased as the particle size to be removed from the liquid is decreased. The length also should be increased for the same particle size as the bowl diameter is decreased. To help the engineers choose a reasonable bowl diameter, the statistical relationship between the bowl diameter and the capacity of the international products is obtained and presented.

Keywords

References

  1. Recors, A. and Sutherland, K., Decanter Centrifuge Handbook, Elsvier Advanced Technology, 2001
  2. White, F.M., Viscous Fluid Flow, McGraw-Hill Book Co., 1981
  3. Maeng, J. S., Suh, Y. K. and Kim, K. C., Fluid Mechanics(in Korean), Byung-Jin Pub. Co., 2003
  4. Benning, J. L., 'Development of Altemative Crab Claw Processing Systems to Minimize Environmen- tal Impact,' M.S. Thesis of Virginia Polytechnic Institute and State University, 1997
  5. Zytner, R. G., Lecture Note avaliable from the Web http:/www.eos.uoguelph.ca/webfiles/zytner, 2003