DOI QR코드

DOI QR Code

Study on Utilizing Resources in Ecopolis - Evaluation of Energy floors of Sewage for Enhanced energy system of residence -

생태도시에서의 자원활용에 관한 연구 - 주택 에너지 시스템 개선을 위한 하수 에너지흐름 분석 -

  • Published : 2003.09.01

Abstract

When the city water was heated for the optimum use of unused energy, the energy flows and losses were calculated and evaluated to improve the value of heated water systems at dwelling side. To obtain this purpose, it was simulated on heat flows under two conditions like with heat pumps or not and calculated the energy sayings. Furthermore, recycling water system was suggested for enhancing the value of heated water system. From this results, the energy flows without heat pumps showed that it was 3-4 percents of heat losses from pipes, 62 percents of energy savings from hot water uses and 34 percents of unutilized heat. When the heated water system adopt the recycling water system at dwelling side, it was improved 12 percents of total energy sayings.

Keywords

References

  1. 박준택, 2003, 미활용에너지의 현황과 전망, 대한설비공학회 2003년도 하계학술발표대회 논문집, 398-403pp
  2. Ichiro, T.S., 1992, Effective use of unused energies, 66, The society of Heating, Airconditioning and sanitary engineers of Japan, 413-417pp
  3. Shimoda, Y., M. Mizuno, S.Kametani, T. Momose and T.Kanaji, 1996, Evaluation Method of Energy Saving Availability by utilizing urbah unused thermal energy, transactions of SHASEJ, 61, 67-77
  4. 落合, 長野, 中村, 山縣, 渡边,1992, 廢熱利用による地域熱供給システムの構成と許憤, 空氣調和${\cdot}$衛生工學會學術講演會講演論文集,965-972pp
  5. 水野槍, 野田博和, 1999, 工場廢熟活用地域冷暖 と水道管による住宅への熱サービスの結合の考察, エネルギー資源争倉第18回研究吏表合講演論文集, 157-160pp
  6. 野田博和, 水野稔, 鄭用賢, 1997, 住宅用熱源として水道の利用に関する研究, 空気調和${\cdot}$衛生工學會近畿支部學術講演會論文集, 47-50pp
  7. Chung, Y.H, M. Mizuno, Y .Simimoda,1998, Study on energy saving properties by using city water as a heat source for dwellings, Joumal of Air conditioning and refrigeration, 168-176pp.
  8. 野田専和, 水野稔, 鄭用賢, 1998, 住宅用熱源として水道の利用に関する研究(その2 地域レベルにおけるシステム導入の検討), 空気調和${\cdot}$衛生工學會學術講演會論文集, 37-740pp.
  9. 정용현, 2003, 생태도시에서의 자원활용에 관한 연구-하수 에너지 활용을 위한 보유열량 평가-, 한국환경과학회지, 12(6), 583-591 https://doi.org/10.5322/JES.2003.12.6.583
  10. 大阪市水道局, 1996, 水道局事業年報 98pp
  11. 空気調和${\cdot}衛生工學會,1996, 空気調和${\cdot}衛生工學會便覧, 丸善, 5(12), 238
  12. 村上三郎, 1993, 水使用行篤分析に基づく集合住宅の使用水量像刺に関する研究, 日本建築學會計毒系論文報告書, 409, 304-312
  13. 金地孝行, 1994, 都市未利用エネルギ-活用可能性許債のため熱源器機性能モデルの検討, 空気調和${\cdot}$衛生工學會近畿支部研究合論文集, 47-50pp
  14. Octave, L., 1996, Understanding engineering thermo, Prince-Hall, Inc., 219pp
  15. 早川一也, 1972, 地域冷壊虜計畵, 丸善株式會社, 115pp