Flue gas from apartment heating gas boiler is exhausted outside through an exhaust duct mounted horizontally in a vertical row on the wall. The flue gas includes nitrogen-oxides (NOx) and carbon monoxide. To investigate the possible entrainment of the flue gas into the apartments through the windows, a large eddy simulation (LES) based numerical method is utilized. Distribution of the velocity intensity and temperature around the exhaust ducts is presented for three numerical parameters: exhaust velocity, temperature of the flue gas, and exhaust duct length. The flow field visualized with particles inserted at the ends of the ducts is also presented. The results clearly show that the exhausted flue gas may flow into the apartments when the windows are open.

Keywords

References

  1. J. Korean Institute of Gas v.2 no.1 Analysis of the characteristics of flue gas in infrared mobile heaters for gas room heating Kim,Y.G.;Kweon,J.R.;Kim,C.K.
  2. Korean J. Air-Conditioning and Refrigeration Eng. v.12 no.1 Prediction of the ventilation performance in a kitchen with various locations of gas range and window Kim,K.H.;Lee,J.H.;Park,M.S.;Lee,D.W.
  3. Proc. 2001 SAREK Winter Conference Estimating exhaust flow rate of a vertical exhaust duct in a high-rise building Kim,S.D.;Kim,K.B.
  4. Monthly Weather Review v.91 General circulation experiments with the Primitive equations-I.The basic experiment Smagorinsky,J.
  5. Fire dynamics simulator technical reference guide(v.3) McGrattan,K.B.;Baum,H.R.;Rehm,R.G.;Hamins,A.;Forney,G.P.;Floyd,J.E.;Hostikka,S.