열펌프 시스템의 규모 결정을 위한 온돌난방부하 특성

Characteristics of Ondol Heating Load for the Determination of Heat Pump Power


초록

To find out heating load and to determine the power of heat pump compressor for the Ondol room heating the COP of heat pump, the variation of Ondol room air temperature, the variation of ambient temperature and power consumption of heat pump are analyzed. The results from this study were summarized as follows: 1. The COP of the heat pump in close loop decreased as the ambient air temperature. The COP was 2.26 when the temperature difference of condenser was $20\pm3^{\circ}C$. 2. The Ondol surface temperature was $25\pm3^{\circ}C$ when the hot water of $40^{\circ}C$ was supplied from hot water storage tank to the Ondol and the temperature difference between the Ondol surface and the room air temperature was $7~8^{\circ}C$. 3. The ratio of thermal conduction heating load to total heating load in Ondol heating space was found to be 83% and ratio of ventilation heating load was 17%. Therefore, the thermal conduction heating load was confirmod to be a major heating load in Ondol heating space. 4. In case of the ambient temperature of $3.2^{\circ}C$, the efficiency of heat exchange of Ondol heating system was 85%. 5. The heating load per Ondol heating surface area and volume of Ondol room space were theoretically analyzed. In case of the room temperature of $20^{\circ}C$ and the ambient temperature of $-3.2~3.8^{\circ}C$, the heating load per Ondol surface area was 115.8~167.6kJ/h ㆍ㎥ and per Ondol mom space volume was 50.2~72.7kJ/h ㆍ㎥. 6. The compressor power of heat pump fur the Ondol room heating could be determined with the heating load analyzed in this study In case of the Ondol room air temperature of 17~2$0^{\circ}C$ and the ambient temperature of -5~3.8$^{\circ}C$, the compressor power of heat pump per Ondol surface area was analyzed to be $2.3\times10^{-2}psm^2$, and per volume of Ondol room space $1.0\times10^{-2}1.4\times10^{-2}ps/m^2$ps.

키워드

참고문헌

  1. 김명헌, 2000, “열펌프-잠열축열 시스템을 이용한 온돌의 난방 특성”, 석사학위논문, 충북대학교 대학원
  2. 김소연, 안경태, 강재식, 조동우, 이윤구, 1995, “건축물의 열부하 예측 모델 개발에 관한 연구”, 대한건축학회논문집, 11권 12호, 통권 86호, pp213-222
  3. 박종길, 2002, “열펌프-잠열축열 온돌시스템의 난방 시뮬레이션 모델 개발”, 박사학위 논문, 충북대학교 대학원
  4. 손장열, 안병욱, 1991, “온돌난방 공간의 내표면 대류열전달 특성에 관한 연구”, 공기조화 냉동공학 논문집, 3권 5호, pp. 376-385
  5. 안병욱, 손장열, 1990 “온돌난방 공간의 실온예측에 관한 연구”, 대한건축학회학술발표논문집 10권 1호, pp. 321-324.
  6. 조수, 손장열, 1992, “잠열재 이용 온수온돌의 난방공간 실내온도 분포에 관한 연구”, 대한건축학회논문집, 8권 4호, 통권 42호 pp. 81-88.
  7. Chapon, C. and M. Delandre, 1991. "Air Conditioning by Heat Pumps on a Water Loop", ASHRAE Trans, Vol 97 Part 1.
  8. Kavanaugh, S.P. J.G. Woodhouse, and J.R. Carter, 1991. "Test Results of Water-to Air Heat Pumps with High Cooling Efficiency for Ground-Coupled Applications", ASHRAE Syposium.