Ion-Sensitive Field Effect Transistor-Based Multienzyme Sensor for Alternative Detection of Mercury ions, Cyanide, and Pesticide

  • 발행 : 2003.06.01

초록

Various groups of industrial and agricultural pollutants (heavy metal ions, cyanides, and pesticides) can be detected by enzymes. Since heavy metal ions inhibit urease, cyanides inhibit peroxidase, organophosphorus and carbamate pesticides inhibit butyrylcholinesterase, these enzymes were co-immobilized into a bovine serum albumin gel on the surface of an ion-sensitive field effect transistor to create a bioprobe that is sensitive to the compounds mentioned above. The sensitivity of the present sensor towards KCN corresponded to $1\;\mu\textrm{M}$ with 1 min of incubation time. The detection limits for Hg(II) ions and the pesticide carbofuran were 0.1 and $0.5\;\mu\textrm{M}$, respectively, when a 10 min sensor incubation time in contaminated samples was chosen. The total time for determining the concentrations of all species mentioned did not exceed 20 min.

키워드

참고문헌

  1. Biosens. Bioelectron v.5 Inhibited enzyme electrodes;A sensor for low levels of $H_2$S and HCN Albery,W.J.;A.E.G.Cass;B.P.Mangold;Z.X.Shu https://doi.org/10.1016/0956-5663(90)80018-9
  2. Electroanal v.8 Electrochemical biosensors for inhibitor determination: Selectivity and sensitivity control Budnikov,H.C.;G.A.Evtugyn https://doi.org/10.1002/elan.1140080821
  3. Food Toxicology Contaminants and Additives Concon,J.M.
  4. Biosens. Bioelectron. v.10 The detection and identification of metal and organic pollutants in portable water using enzyme assays suitable for sensor development Cowell,D.C.;A.A.Dowmann;T.Ashcroft https://doi.org/10.1016/0956-5663(95)96926-P
  5. Biosens. Bioelectron. v.12 Increased paraoxon detection with solvents using acetylcholinesterase inactivation measured with a choline oxidase biosensor Fennouh,S.;V.Casimiri;C.Burstein https://doi.org/10.1016/S0956-5663(97)87055-8
  6. Biosens. Bioelectron v.8 Detection of heavy metal salts with biosensors built with an oxygen electrode coupled to various immobilized oxidases and dehydrogenases Gayet,J.C.;A.Haouz;A.Geloso-Meyer;C.Burstein https://doi.org/10.1016/0956-5663(93)85030-R
  7. Handbook of Pesticide toxicology v.3 Hayes,W.J.;E.R.Laws
  8. J. Mictobiol. Biotechnol. v.11 Effect of ionic copper toxicity on the growth of green algae, Selenastrum capricornutum Kim,M.K.;R.E.H.Smith
  9. Biosens. Bioelectron v.8 Enzyme sensors for the detection of pesticides Marty,J.L.;N.Mionetto;T.Noguer;F.Ortega;C.Roux https://doi.org/10.1016/0956-5663(93)85007-B
  10. Biosens. Bioelectron v.11 Disposable cuvette test with integrated sensor layer for enzymatic determination of heavy metals Preininger,C.;O.Wolfbeis https://doi.org/10.1016/0956-5663(96)87657-3
  11. Biosens. Bioelectron v.7 Sensitive detection of pesticides using amperometric sensors based on cobalt phthalocyanine-modified composite electrodes and immobilized Scladal,P.;M.Mascini https://doi.org/10.1016/0956-5663(92)85029-A
  12. Anal. Chem. v.62 Cyanide detection using a substrate regenerating, Peroxidase-based biosensor Smit,M.H.;A.E.G.Cass https://doi.org/10.1021/ac00221a004
  13. J. Microbiol. Biotechnol. v.11 Isolation and characterization of antibiotic and heavy metal-resistant Pseudomonas aeruginosa from different polluted waters in Sohag District, Egypt Soltan,E.M.
  14. Anal. Chem. v.68 $H_2O_2$-generating peroxidase electrodes as reagentless cyanide sensors Tatsuma,T.;N.Oyama https://doi.org/10.1021/ac951033d
  15. Biosens. Bioelectron. v.5 Studies on acetylcholine sensor and its analytical application based on the inhibition of cholinesterase Tranh-Minh,C.;P.C.Pandey;S.Kumaran https://doi.org/10.1016/0956-5663(90)80035-C
  16. Principles of Enzymology for the Food Sciences Enzyme inhibitors Whitaker,J.R.
  17. Sens. Actuat v.B24;B25 Application of urease conductometric biosensor for heavy-metal ion determination Zhylyak,G.A.;S.V.Dzyadevich;Y.I.Korpan;A.P.Soldatkin;A.V.El'skaya