Development of High Performance Ozone Generating Controller

다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발

  • 이홍희 (울산대 전기전자정보시스템공학부) ;
  • 김형준 (울산대 공대 제어계측학과)
  • Published : 2003.05.01

Abstract

When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.

Keywords

References

  1. R. Ouellet, M. Barbier, and P. Cheremisinoff, 'Low Temperature Plasma Technology Applications.' Ann Arbor, Mi : Ann Arbor Science Publ., 1980
  2. U. Kogelschatz, 'Industrial Ozone Production', Proc. of Int. Ozone Symp., Switzerland, pp. 253-265, 1999
  3. C. Gutierrez-Tapia, 'Perturbative Method for Ozone Synthesis From Oxygen in a Single Discharge' Proc. of the IEEE, Vol. 22, No. 5, pp. 979-985, October 1994 https://doi.org/10.1109/27.338316
  4. L.M.L.F Hosselet, 'Ozonbildung mittels elektrischer Entladungen', TH-Report 71-E-19, TH Eindhoven, 1971
  5. P. Pignolet, et al., 'Ozone generation by point to plane corona discharge,' J.Phys. D: Appl. Phys., Vol. 23, pp. 1069-1072, 1990 https://doi.org/10.1088/0022-3727/23/8/011
  6. I.D. Chalmers, R C Baird and T Kelly, 'Control of an ozone generator-theory and practice' Meas. Sci. Technol. 9, pp.983-988. Printed in the UK. 1998 https://doi.org/10.1088/0957-0233/9/6/016
  7. W.J.M. Samaranayake, et al., 'Ozone Production by Pulsed Power in Dry Air', H. Pulsed Power Conference, Digest of Technical Papers. 12th IEEE International, Vol 2, pp. 1326-1329, 1999 https://doi.org/10.1109/PPC.1999.823771
  8. Y.L.Feng, et al., 'Next generation current-source soft-switched PDM and PWM hybrid mode inverter for silent discharge ozone generating tube drive'Power Electronics and Motion Control Conference Proceedings, Vol. 1, pp. 312 -317, 2000 https://doi.org/10.1109/IPEMC.2000.885421
  9. 송 현직, 우 성훈, 이 상근, '중첩형 오존발생기에 관한 연구(I)' 97 대한전기학회 창립 50주년 하계학술대회 논문집, DHP 5, pp.1724-1726, 1997