Abstract
In room acoustics, reverberation time is an important acoustic parameter. However it is often difficult to measure short reverberation times at low frequencies with a traditional band pass filter bank if the product of filter bandwidth (B) and reverberation time (T) is small. It it well known that the minimum permissible product of bandwidth and reverberation time of the traditional band pass filter is at least 16. This strict requirement makes it difficult to measure short reverberation times of an acoustic room at low frequencies exactly. In order to reduce this strict requirement, in the previous paper, the wavelet filter bank was developed and the minimum permissible product of bandwidth and reverberation time was replaced with 4. In the present paper it is demonstrated how the short reverberation times of an practical room at low frequencies are successfully measured by using the wavelet filter bank and the results are compared with the traditional method using a band past filer bank.