DOI QR코드

DOI QR Code

Pressure Control of a Pneumatic Conrol system with a long Transmission Line

긴 전달관로를 갖는 공압제어계의 압력 제어

  • 장지성 (부경대학교 기계공학부) ;
  • 이광국 (부경대학교 제어기계공학과) ;
  • 최명수 (부경대학교 기계공학부)
  • Published : 2003.04.01

Abstract

In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, it a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feedforward controller to regulate command fallowing performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model or the transmission line. Therefore, the designed controller can be utilized for the Performance improvement of a Pressure control system with a long transmission line using compressible fluid.

Keywords

References

  1. Park, J. G., 1997, 'Friction Compensation for Impedance Control of Pneumatic Manipulator,' Transactions of the KSME, A, Vol. 21, No.2, pp. 252 -260
  2. Tukamoto, N., Kawakami, Y. and Nakano, K., 2002, 'An Application of Gain-Scheduling Control to a Pneumatic Servo System,' Transactions of the Japan Fluid Power System Society, Vol. 33, No. I, pp. 15-20 https://doi.org/10.5739/jfps.33.15
  3. Shen, T., Tamura, K. and Kaminaga, H., 2000, 'Robust Nonlinear Control of Parametric Uncertain systems with Unknown Friction and Its Application to a Pneumatic Control Valve,' ASME Journal of Dynamic Systems, Measurement, and Control, Vol. 122, pp. 257-262 https://doi.org/10.1115/1.482451
  4. Rohmann, C. P. and Grogan, E. C., 1957, 'On the Dynamics of Pneumatic Transmission Lines,' Transactions of the ASME, Vol. 97, pp. 853-874
  5. Yoshioka, M. and Morikawa, Y., 1981, 'Transient Response of Volume-Terminated Pneumatic Transmission Lines,' Transactions of the Society of instrument and Control Engineers, Vol. 17, No.9, pp. 920-926 https://doi.org/10.9746/sicetr1965.17.920
  6. Yoon, S. J. and Son, B. J., 1994, 'The Propagation Characteristics of the Pressure in the Volume Loaded Fluid Transmission Line,' Transactions of the KSME, Vol. 18, No. 11, pp. 3075-3083
  7. Noritugu, T. and Takaiwa, M., 1995, 'Design of Pneumatic Servo System Using Disturbance Observer,' Transactions of the Society (if instrument and Control Engineers, Vol. 31, No. 1, pp. 82-88 https://doi.org/10.9746/sicetr1965.31.82
  8. Mccloy, D. and Martin, H. R., 1980, 'Control of Fluid Power,' JOHN WILEY & SONS INC., pp. 255-258
  9. Hanafusa, H., 1982, 'Design of Electrohydraulic Servo Control Systems for Articulated Robot Arm Control,' . The Japan Hydraulics & Pneumatics Society, Vol. 20, No.7, pp. 429-436
  10. Doyle, J. C., Francis, B. A. and. Tannenbaum, A. R., 1992, 'Feedback Control Theory,' Macmillan Publishing Company, pp, 51-56

Cited by

  1. Dynamic Analysis of Driving Mechanism for Displacement Controlled Automatic Drug Injector vol.37, pp.3, 2013, https://doi.org/10.3795/KSME-A.2013.37.3.303