DOI QR코드

DOI QR Code

An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR

비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구

  • 김우석 (아주대학교 대학원) ;
  • 손덕영 (아주대학교 대학원 기계공학과) ;
  • 박영무 (아주대학교 기계 및 산업공학부) ;
  • 유재석 (아주대학교 기계 및 산업공학부) ;
  • 이종화 (아주대학교 기계 및 산업공학부)
  • Published : 2003.03.01

Abstract

A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.

Keywords

References

  1. Sergei, S. and Collings, N., Hands, T., Peckham, M. and Burrell, J., 1998, 'Fast Response NO/HC Measurements in the cylinder and Exhaust Port of a DI Diesel Engine,' SAE980788
  2. Robert M. Green, 2000, 'Measuring the Cylinder-to-Cylinder EGR Distribution in the intake of Diesel Engine During Transient Operation,' SAE 2000-01-2866
  3. Cory Sutela and Nick Collings, Tim Hands, 2000, 'Real Time $CO_2$ Measurement to Determine Transient Intake Gas Composition under EGR Conditions,' SAE 2000-01-2953
  4. Haifeng Liu and James S. Wallace, 1999, 'An Experimental Investigation into the Characteristics of a Fast-response Flame Ionization Detector for In-cylinder Sampling,' SAE 1999-01-3538
  5. Cory Sutela and Nick Collings, Tim Hands, 1999, 'Fast Response $CO_2$ Sensor for Automotive Exhaust Gas Analysis,' SAE 1999-01-3477
  6. Summers, T. and Collings, N., 1995, 'Modelling the Transit Time of a Fast Response Flame Ionisation Detector During In-Cylinder Sampling,' SAE950160
  7. Liu, H. and Wallace, James S., 1999, 'An Experimental Investigation into the Characteristics of a Fast-Response Flame Ionization Detector for In-Cylinder Sampling,' SAE1999-01-3538
  8. Klmlo Mlyatake, Kozo Ishida, and Hiroji Kohsaka, Neal Harvey, 1990, 'Fast Response NDIR for Real-Time Exhaust Measurement,' SAE 900501
  9. Chan, S. H., 1996, 'Measurement of concentrations of transient gases using a conventional NDIR analyzer,' Meas. Sci. Technol. https://doi.org/10.1088/0957-0233/7/12/013
  10. Robert M.Green, 2000, 'Measuring the Cylinder-to Cylinder EGR Distribution in the Intake of a Diesel Engine During Transient Operation,' SAE2000-01-2866