DOI QR코드

DOI QR Code

Novel Thallium(I)-Selective Membrane Electrode Based on a Podal Ligand

  • 발행 : 2003.11.20

초록

A PVC-based membrane electrode for thallium(I) ions based on 1,21,23,25-tetramethyl-2,20: 3,19-dimetheno-[H, 2] H, 23H, 25H-bis-[1,3] dioxocino[5,4-i:5',4'-i] benzo [1,2-d: 5.4-d'] bis [1,3] benzodioxocin(II) has been prepared. The electrode displays a linear dynamic range of $1.0{\times}10^{-1}-1.0{\times}10^{-5}$ M, with a Nernstian slope of $59.8{\pm}0.2\;mV\;{decad^-1}$, and a detection limit $5.0{\times}10^{-6}$ M. It has a very fast response time of<10 s and can be used for at least ten weeks without a considerable divergence in potentials. This electrode revealed comparatively good selectivity with respect to alkali, alkaline earth, and some transition and heavy metal ions and was effective in a pH range of 2.0-10.0. It was used as an indicator electrode in potentiometric titration of thallium ion with sulfide ion.

키워드

참고문헌

  1. Moeschlin, S. Clin. Toxicol. 1980, 17, 133. https://doi.org/10.3109/15563658008985073
  2. Bakker, E.; Buhlmann, P.; Pretsch, E. Chem. Rev. 1997, 97,3083. https://doi.org/10.1021/cr940394a
  3. Tamura, H.; Kimura, K. Shono, T. J. Electroanal. Chem.Interfacial Electrochem. 1980, 115, 115. https://doi.org/10.1016/S0022-0728(80)80499-2
  4. Zaifu, H.; Huijie, W.; Weidong, H.; Songhui, Y.; Zhiqiang, L.Chin. J. Appl. Chem. 1991, 8, 25.
  5. Kim, S. M.; Jung, S. U.; Kim, J.; Lee, S. S.; Kim, J. S. J. KoreanChem. Soc. 1993, 37, 773.
  6. Ouchi, M.; Shibutani, Y.; Yakabe, K.; Shono, T.; Shintani, H.;Yoneda, Y.; Hakushi, T.; Weber, E. Bioorg. Med. Chem. 1999, 7,1123. https://doi.org/10.1016/S0968-0896(98)00274-0
  7. Kimura, K.; Tatsumi, K.; Yokoyama, M.; Ouchi, M.; Mocerino, M. Anal. Commun. 1999, 36, 229. https://doi.org/10.1039/a902803j
  8. Park, K. S.; Jung, S. O.; Lee, S. S; Kim, J. S.; Mocerino, M. Bull.Korean Chem. Soc. 2000, 21, 909.
  9. Yamashoji, Y.; Tanaka, M.; Nagamune, S.; Ouchi, M.; Hakushi,T.; Shono, T. Anal. Sci. 1991, 7, 485. https://doi.org/10.2116/analsci.7.485
  10. Masuda, Y.; Yakabe, K.; Shibutani, Y.; Shono, T. Anal. Sci. 1994,10, 491. https://doi.org/10.2116/analsci.10.491
  11. Ouchi, M.; Hakushi, T. Coord. Chem. Rev. 1996, 148, 171. https://doi.org/10.1016/0010-8545(96)01208-8
  12. Katsu, T.; Ido, K.; Takashi, K.; Yokosu, H. Sens. Actuators B2002, 87, 331. https://doi.org/10.1016/S0925-4005(02)00264-2
  13. Javanbakht, M.; Shabani-Kia, A.; Darvich, M. R.; Ganjali, M. R.;Shamsipur, M. Anal. Chim. Acta 2000, 408, 75. https://doi.org/10.1016/S0003-2670(99)00771-0
  14. Ganjali, M. R.; Moghimi, A.; Shamsipur, M. Anal. Chem. 1998,70, 5259. https://doi.org/10.1021/ac980340r
  15. Fathi, M. R.; Darviche, F.; Ganjali, M. R. Anal. Lett. 2000, 30,1025.
  16. Rouhollahi, A.; Ganjali, M. R.; Shamsipur, M. Talanta 1998, 46,1341. https://doi.org/10.1016/S0039-9140(97)00421-9
  17. Shamsipur, M.; Javanbakhat, M.; Mousavi, M. F.; Ganjali, M. R.;Lippolis, V.; Garau, A.; Tei, L. Talanta 2001, 55, 1047. https://doi.org/10.1016/S0039-9140(01)00434-9
  18. Shamsipur, M.; Rouhani, S.; Sharghi, H.; Ganjali, M. R.; Eshghi,H. Anal. Chem. 1999, 71, 4938. https://doi.org/10.1021/ac990167e
  19. Ganjali, M. R.; Poursaberi, T.; Babaei, L. H. A.; Rouhani, S.;Yousefi, M.; Kargar-Razi, M.; Moghimi, A.; Aghabozorg, H.;Shamsipur, M. Anal. Chim. Acta 2001, 440, 81. https://doi.org/10.1016/S0003-2670(01)01051-0
  20. Ganjali, M. R.; Naji, L.; Poursaberi, T.; Taghizadeh, M.; Pirelahi,H.; Yousefi, M.; Yeganeh-Faal, A.; Shamsipur, M. Talanta 2002,58, 359. https://doi.org/10.1016/S0039-9140(02)00289-8
  21. Shamsipur, M.; Rouhani, S.; Ganjali, M. R.; Sharghi, H.; Eshghi,H. Sens. Actuators 1999, B59, 30.
  22. Umezawa, Y.; Umezawa, K.; Sato, H. Pure Appl. Chem. 1995, 67,507. https://doi.org/10.1351/pac199567030507

피인용 문헌

  1. Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade vol.8, pp.4, 2008, https://doi.org/10.3390/s8042331
  2. Novel Thallium(I)-Selective Membrane Electrode Based on a Podal Ligand. vol.35, pp.17, 2004, https://doi.org/10.1002/chin.200417168
  3. Construction of a Highly Selective and Sensitive La(III) Sensor Based onN-(2-Pyridyl)-N′-(4-methoxyphenyl)-thiourea for Nano Level Monitoring of La(III) Ions vol.18, pp.11, 2006, https://doi.org/10.1002/elan.200603497
  4. Silver(I)-selective membrane potentiometric sensor based on two recently synthesized ionophores containing calix[4]arene vol.45, pp.7, 2009, https://doi.org/10.1134/S1023193509070155
  5. La(III) Selective Membrane Sensor Based on a New N-N Schiff's Base vol.26, pp.1, 2003, https://doi.org/10.5012/bkcs.2005.26.1.038
  6. Novel Triiodide PVC-Based Membrane Sensor Based on a Charge Transfer Complex of Iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone vol.26, pp.11, 2005, https://doi.org/10.5012/bkcs.2005.26.11.1738
  7. Zn2+ PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one vol.26, pp.4, 2005, https://doi.org/10.5012/bkcs.2005.26.4.579
  8. Sub-Micro Molar Monitoring of La3+ by a Novel Lanthanum PVC-Based Membrane Sensor Based on 3-Hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide vol.27, pp.10, 2003, https://doi.org/10.5012/bkcs.2006.27.10.1581
  9. Novel Tm(III) Membrane Sensor Based on 2,2'-Dianiline Disulfide and Its Application for the Fluoride Monitoring of Mouth Wash Preparations vol.27, pp.9, 2006, https://doi.org/10.5012/bkcs.2006.27.9.1418
  10. Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base vol.27, pp.9, 2003, https://doi.org/10.5012/bkcs.2006.27.9.1439
  11. Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor vol.28, pp.1, 2003, https://doi.org/10.5012/bkcs.2007.28.1.068