Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline
단열배관의 온라인 두께측정시스템 개발
Abstract
The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.