The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR)

Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교

  • Kim, Jin-Bae (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital) ;
  • Kang, Chung-Hwan (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital) ;
  • Kang, Sung-Jin (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital) ;
  • Park, Soo-In (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital) ;
  • Park, Jong-Won (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital) ;
  • Kim, Yeong-Su (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital) ;
  • Kim, Seung-Sik (Dept. of Radiology, Soon Chun Hyang University Bucheon Hospital)
  • 김진배 (순천향대학교 의과대학 부속 부천병원 방사선과) ;
  • 강충환 (순천향대학교 의과대학 부속 부천병원 방사선과) ;
  • 강성진 (순천향대학교 의과대학 부속 부천병원 방사선과) ;
  • 박수인 (순천향대학교 의과대학 부속 부천병원 방사선과) ;
  • 박종원 (순천향대학교 의과대학 부속 부천병원 방사선과) ;
  • 김영수 (순천향대학교 의과대학 부속 부천병원 방사선과) ;
  • 김승식 (순천향대학교 의과대학 부속 부천병원 방사선과)
  • Published : 2002.05.24

Abstract

DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

DR은 방사선과 뿐만 아니라 병원전체의 생산성 및 업무의 효율성에서 중요한 요소로 자리잡아가고 있다. DR환경은 CR보다 다양한 Parameter를 가지고 있어 양질의 의료서비스 제공이 가능하다. 현재 각 병원의 방사선과는 Film-Screen system에서 Full-PACS를 통한 DR 환경으로 변화하고 있다. Full-PACS를 사용하고 있는 본원에서는 DR환경에서의 일반촬영 System중 CR과 DDR의 최적노출조건과 그에 따른 Image quality가 어떻게 표현되는 지 알아보고자 본 연구에 임하게 되었다. 본 실험을 통하여 CR과 DDR의 Image quality는 같은 노출조건 하에서는 DDR이 더욱 우수하다는 것을 알 수 있었다. 그리고 DDR system에서도 AEC를 사용했을 때의 Image에 대한 점수가 사용하지 않았을 때보다 조금 더 높은 것을 알 수 있다. 특히 Skull, Chest부분에서는 DDR의 AEC기능이 Image quality를 향상시키는데 유용함을 간접적으로 알 수 있었다. (AEC기능이란 피사체를 통과한 X선을 Detector내에 있는 Ion chamber를 이용하여 전리전류를 검출하는 기구로서 적정농도 도달 시 X선의 조사를 제어하도록 되어있다.) 이 기능은 다양한 피사체의 두께에 따른 노출조건을 고려하지 않아도 적정농도를 나타낼 수 있기 때문에 보다 손쉬운 촬영이 이루어질 수 있다. 이 실험결과로 좋은 Image quality를 얻기 위해서는 적절한 노출조건의 선정이 중요함을 알 수 있었다. 앞으로도 무한한 발전 가능성이 있는 DDR system에 대한 연구가 좀 더 필요하겠다.

Keywords