초록
The operation results of the 2kW class plate type reformer, which has several advantages compared with the tubular burner type reformer, are analyzed. This plate type reformer is composed of six combustion chambers and five reforming chambers by turns. The methane conversion rate at 1.6 absolute pressure is about 84%, which is reasonably similar to theoretical value, 85.3%. Though the abrupt interruption was made just by the carbon deposition during heating the fuel line to combustion chambers around 200 hours operation, the overall steady state operation is more than 450 hours. These operation results show the verification of long run performance and the possibility of direct connection between plate reformer and fuel cell stack.