주입선 형태가 티타늄 주조관의 변연재현성에 미치는 영향

THE EFFECT OF SPRUE DESIGN ON THE MARGINAL REPRODUCIBILITY OF CAST TITANIUM CROWNS

  • 박재경 (부산대학교 치과대학 보철학교실) ;
  • 정창모 (부산대학교 치과대학 보철학교실) ;
  • 전영찬 (부산대학교 치과대학 보철학교실)
  • Park Jae-Kyoung (Department of Dentistry, Graduate School, Pusan National University) ;
  • Jeong Chang-Mo (Department of Dentistry, Graduate School, Pusan National University) ;
  • Jeon Young-Chan (Department of Dentistry, Graduate School, Pusan National University)
  • 발행 : 2002.08.01

초록

There has been a great interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However the high melting temperature and chemical reactivity of titanium necessitates casting systems different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new developments in Ti casting systems, inadequate mold filling and internal porosity are frequently observed casting defects. Therefore, the study on the fabrication technique including sprue design to solve these casting defects is still necessary. In this study to evaluate the effect of sprue design on the castability of simulated cast titanium crowns, 10 cylindrical cast crowns for each group with four different sprue design(Single group. Double group, Runner bar group. Reservoir group) were fabricated. An impression of the entire casting margin was made and cut at $90^{\circ}$ intervals, and the sections were photographed in a microscope at $100{\times}$ magnification to record marginal discrepancy. The internal porosities of the cast crowns were disclosed by radiographs. Within the limits of this study. the following conclusions were drawn. 1. The overall mean marginal discrepancies for each group were as follows: Double group, $43.65{\mu}m$; Reservoir group, $50.27{\mu}m$; Single group, $54.17{\mu}m$; Runner bar group, $58.90{\mu}m$ (p<0.05). 2. The mean of marginal discrepancies for wax patterns was $10.65{\mu}m$. 3 The numbers of internal porosity showed the most in Runner bar group followed by Single group, Reservoir group, and Double group.

키워드

참고문헌

  1. Parr GR, Gardner LK, Toth RW. Titanium: the mystery metal of implant dentistry. Dental materials aspects. J Prosthet Dent 1985;54:410-4 https://doi.org/10.1016/0022-3913(85)90562-1
  2. Blackman R, Barghi N, Tran C. Dimensional changes in casting titanium removable partial denture framework. J Prosthet Dent 1991;65:309-15 https://doi.org/10.1016/0022-3913(91)90181-U
  3. Hruska AR, Borelli P. Quality criteria for pure titanium casting, laboratory soldering, intraoral welding, and a device to aid in making uncontaminated castings. J Prosthet Dent 1991;66:561-5 https://doi.org/10.1016/0022-3913(91)90524-Z
  4. Wang RR, Boyle AM. A simple method for inspection of porosity in titanium castings. J Prosthet Dent 1993;70:275-6 https://doi.org/10.1016/0022-3913(93)90065-V
  5. Reclaru L, Meyer J-M. Study of corrosion between a titanium implant and dental alloys. J Dent 1994;22:159-68 https://doi.org/10.1016/0300-5712(94)90200-3
  6. Andersson M, Bergman B, Bessing C, Ericson E, Lundquist P and Nilson H. Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odont Scand 1989;47:279-86 https://doi.org/10.3109/00016358909007713
  7. Christer B, Maud B. The castability of unalloyed titanium in three different casting machines. Swed Dent J 1992;16:109-13
  8. Mori T. Titanium: A review of investments for high temperature casting. Aust Prosthodont J 1993;7:31-4
  9. Watanabe I, Watkins JH, Nakajima H, Atsuta M, Okabe T. Effect of pressure difference on the quality of titanium casting. J Dent Res 1997;3:773-9
  10. Her H, Syverud M, Waarli M. Mold filling and porosity in casting of titanium. Dent Mater 1993;9:15-8 https://doi.org/10.1016/0109-5641(93)90098-B
  11. Syverud M, Her H. Mold filling of Ti castings using investments with different gas permeability. Dent Mater 1995;11:14-8 https://doi.org/10.1016/0109-5641(95)80003-4
  12. Sunnerkrantz PA, Syverud M, Her H. Effect of casting atmosphere on the quality of Ti-crowns. Scand J Dent Res 1990;98:268-72
  13. Her H, Syverud M, Waarli M, Jorgensen RB. Casting of dental titanium crowns: surface reactions and dimensional fit. In: Proceedings of the 1990 International Conference on Titanium. Products and Applications. Vol. II . Dayton, Ohio: Titanium Development Association;1990.p.612-2
  14. Mori T, Jean-Louis M, Yabugami M, Togaya T. The effect of investment type on the fit of cast titanium crowns. Aust Dent J 1994;39:348-52 https://doi.org/10.1111/j.1834-7819.1994.tb03104.x
  15. Chai TI, Stein RS. Porosity and accuracy of multiple-unit titanium castings. J Prosthet Dent 1995;73:534-41 https://doi.org/10.1016/S0022-3913(05)80112-X
  16. Chan D, Guillory V, Blackman R, Chung KH. The effects of sprue design on the roughness and porosity of titanium castings. J Prosthet Dent 1997;78: 400-4 https://doi.org/10.1016/S0022-3913(97)70048-9
  17. Al-Mesmar HS, Morgano SM, Mark LE. Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks. J Prosthet Dent 1999;82:15-21 https://doi.org/10.1016/S0022-3913(99)70126-5
  18. D.C.N. Chan, R. Blackman, D.A. Kaiser, K. Chung. The effect of sprue design on the marginal accuracy of titanium castings. J Oral Rehabili 1998;25:424-9
  19. Preston JD, Berger R. Some laboratory variables affecting ceramo-metal alloys. Dent Clin North Am 1977;21:717-28
  20. Vidovic Y, Chung HG, Mori T. Enhancement of a titanium denture frame model: mold temperature and spruing factors. Dent Mater J 1995;14:256-62 https://doi.org/10.4012/dmj.14.256
  21. Kusakari H, Ozaki Y, Hoshino H. Cast titanium crown-for a better fitness and less porosity [in Japanese]. Quintessence Dent Technol 1998;23:17-23.
  22. Ryge G, Kozak SF, Fairhurst CW. Porosities in dental gold castings. J Am Dent Assoc 1957;54:746-54 https://doi.org/10.14219/jada.archive.1957.0125
  23. Brockhurst PJ, McLaverty VG, Kasloff Z. A castability standard for alloys used in restorative dentistry. Oper Dent 1983;8:130-9
  24. Waterstratt, RM. Comments on casting of Ti-13Cu-4.5Ni alloy. Publication No. (NIH)77-1227, DHEW:224-33
  25. Greener EH, Moser JB, Opp J, Szurgot K, Marker BC. Properties of dental castability of Ti and Ti-6Al-4V [abstract 1190]. J Dent Res 1986;65(special issue):301.
  26. Watanabe K, Okawa S, Miyakawa O, Nakano S, Shiokawa N, Kobayashi M. Molten Titanium flow in a mesh cavity by the flow visualization technique. Dent Mater J 1991;10:128-37 https://doi.org/10.4012/dmj.10.128
  27. Eugene PL, Peter M. Titanium and titanium alloys as dental materials. Int Dent J 1993;43:245-53
  28. Shanley JJ, Ancowitz SJ, Fenster RK, Pelleu GB Jr. A comparative study of the centrifugal and vaccum-pressure techniques of casting removable partial denture frameworks. J Prosthet Dent 1981;45:18-23 https://doi.org/10.1016/0022-3913(81)90006-8
  29. Taira M and Moser JB. Studies of Ti alloys for dental castings. Dent Mater 1989;5:45-50 https://doi.org/10.1016/0109-5641(89)90093-6
  30. Miyakawa O, Watanabe K, Okawa S. Layered structure of cast titanium surface. Dent Mater J 1989;8:175-85 https://doi.org/10.4012/dmj.8.175
  31. Takahashi J, Kimura H, Lautenschlager EP, Lin JH, Moser JB, Greener EH. Casting pure titanium into commercial phosphate bonded SiO2 investment molds. J Dent Res 1990;69:1800-5 https://doi.org/10.1177/00220345900690120301
  32. Oda Y, Kudoh Y, Kawada E, Yoshinari M, Hasegawa K. Surface reaction between titanium castings and investments. Bull Tokyo Dent Coll 1996;37:129-36
  33. Compagni R, Faucher RR, Yuodelis RA. Effects of sprue design, casting machine, and heat source on casting porosity. J Prosthet Dent 1984;52:41-5 https://doi.org/10.1016/0022-3913(84)90179-3
  34. Love LD. Sprue design to minimize casting defects in base-metal castings. Quintessence Dent Technol 1987;1l:195-7
  35. Martin KA, Manderson RD. The influence of sprue design on cobalt chromium alloy casting defects. J Dent 1984;12:175-82 https://doi.org/10.1016/0300-5712(84)90052-6
  36. Verrett RG, Duke ES. The effect of sprue attachment design on castability and porosity. J Prosthet Dent 1989;61:418-24 https://doi.org/10.1016/0022-3913(89)90006-1
  37. Martignoni M, Sch nenberger A. Precision Fixed Prosthodontics: Clinical and Laboratory Aspects. Chicago (IL) : Quintessence; 1990.p.292-307
  38. Wight TA, Grisius RJ, Gaugler RW. Evaluation of three variables affecting the casting of base metal alloys. J Prosthet Dent 1980;43:415-8 https://doi.org/10.1016/0022-3913(80)90212-7
  39. Flemings MC. Solidification Processing. McGraw-Hill (NY): 1974.p.221
  40. Barreto MT, Goldberg AJ, Nitkin DA, Mumford G. Effect of investment of casting high-fusing alloys. J Prosthet Dent 1980;44:504-7 https://doi.org/10.1016/0022-3913(80)90068-2
  41. Vincent PF, Stevens L, Basford KE. A comparison of the casting ability of precious and nonprecious alloys for porcelain veneering. J Prosthet Dent 1977;37: 527-36 https://doi.org/10.1016/0022-3913(77)90167-6
  42. Howard WS, Newman SM, Nunez LJ. Castability of low gold content alloys. J Dent Res 1980;59:824-30 https://doi.org/10.1177/00220345800590051301
  43. DeWald E. The relationship of pattern position to the flow of gold and casting completeness. J Prosthet Dent 1979;41:531-4 https://doi.org/10.1016/0022-3913(79)90087-8
  44. Thomson DH. A study of the effect on an increased mold temperature on the casting ability of some nonprecious alloys for porcelain veneers. J Prosthet Dent 1982;48:52-8 https://doi.org/10.1016/0022-3913(82)90047-6
  45. Nitkin DA, Asgar K. Evaluation of alternative alloys to type ill gold for use in fixed prosthodontics. J Am Dent Assoc 1976;93:622-9 https://doi.org/10.14219/jada.archive.1976.0192
  46. Myers GW, Cruickshanks-Boyd DW. Mechanical properties and casting characteristics of a silver-palladium bonding alloy. Br Dent J 1982;153:523-6
  47. Bessing C. Evaluation of the castability of four different alternative alloys by measuring the marginal sharpness. Acta Odontol Scand 1986;44:165-72 https://doi.org/10.3109/00016358609026569
  48. McLean JM, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11 https://doi.org/10.1038/sj.bdj.4802708
  49. Watanabe K. Merit and demerit of runner bar for crown-bridge titanium casting-sink vortex causes internal defects [in Japanese]. Quintessence Dent Technol 1999;24:19-25.
  50. Jang KS, Youn SJ, Kim YS. Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks. J Prosthet Dent 2001;86:93-8 https://doi.org/10.1067/mpr.2001.116168