FIT OF IMPLANT FRAMEWORKS FABRICATED BY ONE-PIECE CASTING, LASER WELDING, SOLDERING, AND ELECTRIC DISCHARGE MACHINING

일체주조법, 레이저용접법, 납착법, 방전가공법에 의해 제작된 임플란트 보철물의 적합도에 관한 연구

  • Seol, Young-Hoon (Department of Prosthodontics, College of Dentistry, Pusan National University) ;
  • Jeong, Chang-Mo (Department of Prosthodontics, College of Dentistry, Pusan National University) ;
  • Jeon, Young-Chan (Department of Prosthodontics, College of Dentistry, Pusan National University) ;
  • Kang, Sung-Won (Department of naval architecture and ocean engineering, College of Engineering, Pusan National University)
  • 설영훈 (부산대학교 치과대학 치과보철학교실) ;
  • 정창모 (부산대학교 치과대학 치과보철학교실) ;
  • 전영찬 (부산대학교 치과대학 치과보철학교실) ;
  • 강성원 (부산대학교 공과대학 조선해양공학과)
  • Published : 2002.04.01

Abstract

The purpose of this study was to measure and compare the strains produced by screw-tightening implant frameworks fabricated by aye different fabrication methods; (1) one-piece cast using plastic sleeve, (2) one-piece cast using gold cylinder, (3) laser welding, (4) soldering, and (5) electrical discharge machining, and also to measure and compare the strains produced when the order of screw tightening was changed A research model incorporating eighteen strain gages was made to measure the fit of implant frameworks in three dimensions. Three implants aligned in an arc were fixed on the top ends of the L-shape aluminum bars of the research model, and standard abutments were joined to the implants with abutment screws. Five types of implant framework were placed on the abutments and screwed by a torque wrench using 10 Ncm. Under the conditions of this study, the following conclusions were drawn: 1. The electrical discharge machining group showed the smallest magnitude of strain, followed by the soldering group, the laser welding group, the one-piece cast group using gold cylinder, and the one-piece cast group using plastic sleeve. However, among the magnitude of strain for the remaining groups except the electrical discharge machining group, there were not significant differences. 2. When the order of screw tightening was changed, there were not significant differences in the magnitude of strain. 3. In comparison with the electrical discharge machining group, the laser welding group and the one-piece cast groups showed greater horizontal distortion and the soldering group showed greater horizontal and vertical distortion.

Keywords

References

  1. Albrektsson T. A multicenter report of osseointegrated oral implants. J Prosthet Dent 1988:75-84
  2. Adell R. Ericksson B. Lekholm U. Branemark P-I. Jemt T. A long- term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990:5:347-59
  3. Zarb GA, Schmitt A. A longitudinal clinical effectiveness of osseointegrated dental implants. The Toronto study. Part II. The prosthetic results. J Prosthet Dent 1990: 64: 53-61
  4. Adell R Lekholm U. Rockler B. Branemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981: 10:387-416
  5. Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989: 62:581-5
  6. Carlson B. Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillifac Implants 1994: 9: 90-4
  7. Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983:49: 843-8
  8. Kan JY. Rungcharassaeng K. Bohsali K. Goodacre CJ. Lang BR. Clinical methods for evaluating implant framework fit. J Prosthet Dent 1999;81: 7-13 https://doi.org/10.1016/S0022-3913(99)70229-5
  9. Wee AG. Aquilino SA. Schneider RL. Strategies to achieve fit in implant prosthodontics : A review of the literature. Int J 166 Prosthodont 1999:12:167-78
  10. Taylor RL. Bergman GF: Laboratory techniques for the Branemark system. Chicago. IL. Quintessence. 1990
  11. Tan KB. Rubenstein JE. Nicholls JI. Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant- retained prostheses. Int J Prosthodont 1993:63:346-63
  12. Ziebert GJ. Hurtado A. Glapa C. Schiffieger BE. Accuracy of one-piece castings, preceramic soldering. J Prosthet Dent 1986 ;55: 312-7 https://doi.org/10.1016/0022-3913(86)90110-1
  13. Bruce RW. Evaluation of multiple unit castings for fixed partial dentures. J Prosthet Dent 1964; 14:939-43 https://doi.org/10.1016/0022-3913(64)90023-X
  14. Goll GE. Production of accurately fitting fullarch implant frameworks: Part I-Clinical procedures. J Prosthet Dent 1991:66:37784
  15. Carr AB. Stewart RB. Full-arch implant framework casting accuracy. preliminary in vitro observation for in vivo testing. J Prosthodont 1993; 12:177-83
  16. White GE. Osseointegrated dental technology. chicago: Quitessence Publishing 1993. P78-90
  17. Fusayama T, Wakumoto S, Hosoda H. Accuracy of fixed partial dentures made by various soldering techniques and onepiece casting. J Prosthet Dent 1964:14:334-42
  18. Huling JS. Clark RE. Comparative distortion in three-unit fixed prostheses joined by laser welding, conventional soldering, or casting in one piece. J Dent Res 1977:56:128-34
  19. Rubin JG. Sabella AA. One-piece castings for fixed bridgeworks. J Prosthet Dent 1955:5:843-7
  20. Lim JS, Jeon YC. Jeong CM. Three-dimensional comparision of framework displacements joined by various connection techniques. J Korean Acad Prosthodont 1999:37:358-74
  21. Stackhouse JA. Assembly of dental units by soldering. J Prosthet Dent 1967: 18: 131-9
  22. Hollenback GM, Shell JS. The accuracy of dental appliances assembled by soldering. J Calif Dent Assoc 1965:41:207-10
  23. Sloan RM, Reisbick MH. Preston JD. Post-ceramic soldering of various alloys. J Prosthet Dent 1982:48:686-9
  24. Rosential SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 1st ed. St Louis: CV Mosby, 1988. p. 438
  25. Gegauff A. Rosential S. The seating of one-piece and soldered fixed partial dentures. J Prosthet Dent 1989:62:292-7
  26. Ziebert GJ, Hurtado A. Glapa C, Schiffieger BE. Accuracy of one-piece casting, pre-ceramic and postceramic soldering. J Prosthet Dent 1955: 5: 843-7
  27. Gordon TE, Smith DL. Laser welding of prostheses-an initial report. J Prosthet Dent 1970:24:472-6
  28. Sjogren G, Andersson M, Bergman M. Laser welding of titanium in dentistry. Acta Odontol Scand 1988:46:247-53
  29. Preston JD, Reisbick MH. Laser fusion of selected dental casting alloys. J Dent Res 1975:54:232-8
  30. Smith DL, Burnett AP, Gordon TE. Laser welding of gold alloy. J Dent Res 1972:51: 161-7
  31. Apotheker H. Nishimura I, Seerattan C. Laser-welded vs soldered non precious alloy dental bridges: a comparative study. Lasers in Surgery and Medicine 1984:4: 207-13
  32. Rubenstein JE. Stereo laser-welded titanium implant frameworks : Clinical and laboratory procedures with a summary of 1-year clinical trials. J Prosthet Dent 1995:74:284-93