A Study on the Performance of the Heat Transfer for the Liquid Filling as the Ratio of Working Fluid Volume to Total Volume of the Thermosyphon with Axial Internal Fins

축방향 내부 핀을 가진 열사이폰의 작동유체 체적변화에 대한 열전달 성능에 관한 연구

  • Lee, Jung-Han (Graduate School, Pusan National University) ;
  • Lee, Ki-Baik (School of Mechanical Engineering, Pusan National University) ;
  • Cho, Dong-Hyun (Dept. of Mechanical Design Engineering, Daejin University)
  • Published : 2002.03.31

Abstract

This study concerns the performance of the heat transfer of the thermosyphon having 80 internal fins in which boiling and condensation occur. Water has been used as the working fluid. The Liquid filling as the ratio of working fluid volume to total volume of thermosyphon have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from the experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation we can state that the maximum heat flow rate in the thermosyphon prove to depend upon the liquid fill quantity. The relatively high rates of heat transfer have been achived operating in the thermosyphon with axial internal fins. Also, the thermosyphon with internal micro fins can be used to achieve some inexpensive and compact heat exchangers in low temperature. In addition, it is to obtain the overall heat transfer coefficients and the characteristics as a operating temperature for the practical applications.

본 연구는 축방향 내부 핀을 가진 열사이폰의 작동유체의 체적변화에 대한 응축 및 비등열전달 성능에 관한 연구이다. 열사이폰 내부의 작동유체는 증류수를 사용하였다. 열사이폰의 총체적에 대한 작동유체의 양을 변화시키면서 실험데이터를 산출하였다. 열사이폰의 응축부에 대한 열유속과 응축열전달계수를 구하였으며, 실험결과를 이론모델과 비교분석하였다. 실험결과로부터 열사이폰의 열전달 성능은 작동유체의 체적변화에 크게 의존하였다. 축방향내부 핀을 가진 열사이폰의 열전달 성능은 평튜브로 제작한 열 사이폰보다 크게 향상되었다. 이와 같은 열사이폰을 태양열 분야의 열교환기에 응용할 경우, 고성능화와 소형화할 수 있다. 그리고 산업현장에서 실제적으로 적용하기 위해 총열전달계수를 산출하였다.

Keywords

References

  1. Imura, H., Kusuda, H., Ogata, J., Miyaz, Z., and Sakamoto, N., 1977, 'Heat Transfer in Two-Phase Closed Type Thermosyphons', Trans. of Japan Soc. of Mech. Engrs., 45-493, Series B, 712-722
  2. Larkin, B., S., 1971, Trans. Canada Soc. Mech. Engng., 14-B6, pp. 1-8
  3. Lee Y. and Mital, 1987, Int. J. Heatand Mass Transf., 15-9, pp. 1695-1707
  4. Park, R. J., Lee, Y., 1992, 'Two-Phase Closed Thermosyphon with Two-Fluid Mixtures', 8th IHPC, pp. 220-225
  5. Pioro, L. S., and Pioro, I. L., 1997, 'Industral Two-Phase Thermosyphon', Begell House, New York
  6. Tu C., Xie, G, Hu, C., Gao, Z. and Hong, R., 1984, 'The Two Phase Closed Thermosyphon : an Experimental Study with Flow Pattern and Optimum Fill Charge', China-U.S. Seminar on Twoflows and Heat Transfer, Sian, 395-405
  7. Hahne, E. and Gross, U., 1971, 'The Influence of the Inclination Angle on the Performance of a Closed Two-Phase Thermosyphon', 4th IHPC, London, 125-135, 1981. 2. Larkin, B., 8.,Trans. Canda. Soc. Mech. Engng.,14-B6, pp. 1-8
  8. Negishi, K. and Sawada, T., 1983, 'Heat Transfer Performance of an Inclined Two-Phase Closed Thermosyphon', Int. J. Heat Mass Transfer, 26, No. 8, 1207-1213 https://doi.org/10.1016/S0017-9310(83)80175-6
  9. Yiwei, M., Jifu, L. and Yi, F., 1987, 'The Characteristics of Condensation Heat Transfer in Thermosyphons', 6th IHPC, Grenoble, 597-602
  10. Nitipong, S., Terdtoon, P., Tantakom, P., and Polchai, A., 2001, 'A Performance Limit Model of an Inclined Two-Phase Closed Thermosyphon', Proceedings of the 6th IHP8, pp. 258-268
  11. Nusselt, W., 1916, 'DieOberf1achenkondensation des Wasserdampfes,' Z. Ver. Deut. Ing., 60, 541
  12. Nguyen-Chi, H. and Groll, M., 1981, Entrainment of flooding Limit in a Closed Two-Phase Thermosyphon', 4th IHPC, Tsukuba, 1-6